Agilent 6230 lc tof ms spectrometer

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 6230 LC/TOF MS spectrometer is a high-performance liquid chromatography-time of flight mass spectrometry system. It is designed to provide accurate, sensitive, and reproducible mass analysis of a wide range of compounds.

Automatically generated - may contain errors

4 protocols using agilent 6230 lc tof ms spectrometer

1

Characterization of Isolated Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
1D (1H, 13C, and DEPT) and 2D (HSQC, HMBC, 1H–1H COSY, and NOESY) NMR spectra were obtained on a Bruker AM-500 spectrometer (Bruker, Germany) in CDCl3 or CD3OD (Qingdao Tenglong, China), and TMS was used as an internal reference. IR spectra were scanned on a Nicolet Magna-IR 550 spectrometer (Thermo Nicolet, United States) with KBr pellets. Optical rotations were measured on a Jasco P-1020 digital polarimeter (Jasco, Japan). HR-ESI-MS spectra were obtained on an Agilent 6230 LC/TOF MS spectrometer (Agilent, United States). The prep-HPLC experiment was performed on an Agilent 1260 pump coupled with an analytical preparative ZORBAXSB column (21.2 × 500 m, 5 µm). Silica gel (300–400 mesh, Qingdao Haiyang, China) was used in column chromatography, and Dragendorff’s reagent was used in TLC analysis (GF254 TLC plates, Qingdao Haiyang, China).
+ Open protocol
+ Expand
2

Glycoengineered Antibody-Drug Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
The enzymes of Endo-S, PNGase-F, and AlfC were expressed in E. coli following the reported procedures8 (link), 37 (link), 42 (link), 43 (link). The glycoengineered azido-herceptin (7) and DBCO-MMAE (8) were prepared following our previous paper8 (link). DM1 (N2-deacetyl-N2-(3-mercapto-1-oxopropyl)- maytansine), MMAE (monomethyl auristain E), and SMCC (N-succinimidyl 4-(N-maleimidomethyl)cyclohexane-1-carboxylate) were purchased from Levena Biopharma (Nanjing, China). Other chemical reagents and solvents were purchased from Sinopharm Chemical Reagent Co. (Shanghai, China) or Sigma-Aldrich (Shanghai, China) and used without further purification. The MAbPac RP column (4 μm, 3.0 × 100mm) was purchased from ThermoFisher. Nuclear magnetic resonance (NMR) spectra were measured on a Varian-MERCURY Plus-400 or 500 instrument. ESI-HRMS spectra were measured on an Agilent 6230 LC-TOF MS spectrometer.
+ Open protocol
+ Expand
3

Synthesis and Characterization of PF74

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless indicated otherwise. Compounds were purified via flash chromatography using a Combiflash RF-200 (Teledyne ISCO, Lincoln, NE, USA) with RediSep columns (silica) and indicated mobile phase. 1H and 13C NMR spectra were recorded on a Varian 600 MHz (Agilent Technologies, Santa Clara, CA, USA) or Bruker 400 spectrometer (Bruker, Billerica, MA, USA). Diastereomeric ratio was determined by 1H NMR analysis. Mass data were acquired using an Agilent 6230 TOF LC/MS spectrometer (Agilent Technologies). PF74 was synthesized according to reported procedures43 ,44 (link).
+ Open protocol
+ Expand
4

Synthetic Protocols for Purified Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless indicated otherwise. Compounds were purified via flash chromatography using a Combiflash RF-200 (Teledyne ISCO, Lincoln, NE, USA) with RediSep columns (Teledyne ISCO, Lincoln, NE, USA) (silica) and indicated mobile phase. 1H and 13C NMR spectra were recorded on a Varian 600 MHz (Agilent Technologies, Santa Clara, CA, USA) or Bruker 400 spectrometer (Bruker, Billerica, MA, USA). Diastereomeric ratio was determined by 1H NMR analysis. Mass data were acquired using an Agilent 6230 TOF LC/MS spectrometer (Agilent Technologies, Santa Clara, CA, USA). Compound purity analysis was performed using Agilent 1260 Infinity HPLC (Agilent Technologies, Santa Clara, CA, USA) with an Eclipse C18 column (3.5 μm, 4.6 × 100 mm). HPLC conditions: flow rate, 1.0 mL/min; solvent A, 0.1% TFA in water; solvent B, 0.1% TFA in acetonitrile; gradient (B, %): 0–3 min (5–100), 3–11 min (100), 11–13 min (100–5). Determined purity was >85% for all final compounds.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!