The largest database of trusted experimental protocols

Fitc rat anti mouse cd8a

Manufactured by BD

FITC rat anti-mouse CD8a is a fluorescently labeled monoclonal antibody that binds to the CD8a protein on the surface of mouse T cells. It is used for the identification and quantification of CD8+ T cells in flow cytometry applications.

Automatically generated - may contain errors

2 protocols using fitc rat anti mouse cd8a

1

Immune Cell Phenotyping from Tissues

Check if the same lab product or an alternative is used in the 5 most similar protocols
Immune cells from animal tissue or blood were separated by using HISTOPAQUE®‐1077(10771, Sigma), and then the dissociated lymphocytes were resuspended in PBS and stained for surface markers for 20 minutes with antibodies: PerCP‐CyTM 5.5 rat anti‐mouse CD45 (550994, BD Biosciences, 1:200), FITC rat anti‐mouse CD8a (553030, BD Biosciences, 1:500), APC rat anti‐mouse CD11b (553312, BD Biosciences, 1:200), PE rat anti‐mouse F4/80 (565410, BD Biosciences, 1:200), APC anti‐mouse CD206 (MMR) (141707, BD Biosciences, 1:200), APC mouse anti‐human HLA‐ABC (555555, BD Biosciences, 1:200), APC mouse anti‐human HLA‐DR (560896, BD Biosciences, 1:125), and BV421 rat anti‐mouse CD119 (740032, BD Biosciences, 1:200). Flow cytometry data were obtained on an LSRFortessa, and data analysis was achieved through FlowJo software (Tree Star).
+ Open protocol
+ Expand
2

Splenic T Cell Proportions Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Flow cytometry was performed to detect the proportion of CD4+ or CD8+ lymphocytes in the spleen. Following sacrifice, the spleens were removed under sterile conditions, weighed, and processed into single cell suspensions, which then stained simultaneously with the following antibodies: PerCP-Cy5.5 Rat Anti-Mouse CD3 (BD Biosciences, 560527), BV421 Rat Anti-Mouse CD4 (BD Biosciences, 562891), and FITC Rat Anti-Mouse CD8a (BD Biosciences, 553030), protected from light for 30 min. Labeled cells were fixed with 1% PFA and analyzed with a LSRFortessa X-20 flow cytometer (BD Biosciences, MA, United States) on FACSDiva 8.0.1 software (BD Biosciences). For each sample, corresponding isotype control antibodies were used. CD3+ cells were gated as T lymphocytes, and then the CD4+ and CD8+ populations were analyzed.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!