The largest database of trusted experimental protocols

Hpa027306

Manufactured by Merck Group
Sourced in United Kingdom

HPA027306 is a piece of laboratory equipment manufactured by Merck Group. It is designed to perform a core function within the laboratory setting. Further details on the specific capabilities or intended use of this product are not available.

Automatically generated - may contain errors

2 protocols using hpa027306

1

Immunofluorescence Microscopy Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
For immunofluorescence microscopy, the following antibodies were used: chicken anti-myc (1:300, A-21281; Molecular Probes, Eugene, OR), rabbit anti-SSX2IP (1:150, HPA027306; Sigma-Aldrich, Gillingham, United Kingdom), rabbit anti-PCM1 (1:300, sc67204; Santa Cruz Biotechnology, Santa Cruz, CA), rabbit anti–γ-tubulin (1:250, T5192; Sigma-Aldrich), mouse anti–α-tubulin (1:250, T9026; Sigma-Aldrich), rabbit anti–centrin-2 (1:400, sc27793R; Santa Cruz Biotechnology), mouse anti-Plk4 (1:200, H00010733-B01; Abnova, Taipei, Taiwan), rabbit anti-Cep152 (1:400, A302-480A; Bethyl Laboratories, Montgomery, TX), rabbit anti-hSAS-6 (1:100, sc98506; Santa Cruz Biotechnology), mouse anti-centrobin (1:100, H00116840-B01P; Abnova), rabbit anti-Cep164 (1:200, 45330002; Novus Biologicals, Littleton, CO), mouse anti–C-Nap1 (1:100, 611374; BD Biosciences, San Jose, CA), and rabbit anti-CP110 (1:100, ab99337; Abcam, Cambridge, MA). Secondary antibodies were Alexa Fluor 488–coupled anti-rabbit, Alexa Fluor 594–coupled anti-rabbit, Alexa Fluor 594–coupled anti-mouse, Alexa Fluor 488–coupled anti-mouse, Alexa Fluor 488–coupled anti-chicken, and Cy3-coupled anti-mouse antibodies (all used at 1:1500). For immunoblotting, rabbit anti-SSX2IP (1:1000) and mouse anti–α-tubulin (1:5000) antibodies were used.
+ Open protocol
+ Expand
2

GST Pull-Down Assay with Detailed Antibodies

Check if the same lab product or an alternative is used in the 5 most similar protocols
GST pull-down was performed with Glutathione Sepharose beads (GE healthcare, Chalffint, UK) and carried out in low-salt EBC lysis buffer (150 mM NaCl; 50 mM Tris, pH 7.5; 1 mM EDTA; 0.5% NP40). Antibodies included in this study: CEP131 (A301-425A, Bethyl, WB 1:1000; ab84864, Abcam, Cambridge, UK, IF 1:300), PCM1 (sc-50164, Santa Cruz, IF 1:200), SSX2IP (HPA027306, Sigma-Aldrich, WB 1:1000), MK2 (3042S, Cell Signalling, Danvers, MA, USA, WB 1:1000), HSP27 pS82 (9709, Cell Signalling, WB 1:5000), GST (G7781, Sigma-Aldrich, WB 1:1000), Pericentrin (ab4448, Abcam, IF 1:1000), p38 MAPK (9212S, Cell Signalling, WB 1:1000), p38 MAPK phospho-Thr180/Tyr182 (9216S, Cell Signalling, WB 1:1000), γ-tubulin (T5326, Sigma-Aldrich, IF 1:250), p150 (610473, BD Biosciences, WB 1:10,000), NOGO-B (previously described by Rousseau et al. [66 (link)] WB 1:1000), SRF phospho-Ser103 (4261, Cell Signalling, WB 1:1000), and α-tubulin (T9026, Sigma-Aldrich, IF 1:500).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!