The largest database of trusted experimental protocols

3 protocols using cd45 1 percp cy5

1

Multiparameter Flow Cytometry Analysis of Hematopoietic Reconstitution

Check if the same lab product or an alternative is used in the 5 most similar protocols
Gating strategies can be found in Supplemental Information (Figures S7 and S8). For analysis of mixed chimerism, cells were first stained with LIVE/DEAD Fixable Near-IR Dead Cell Stain Kit (ThermoFisher Scientific) and blocked with TruStain FcX anti-mouse (Biolegend) for 10 min on ice in Cell Stain Buffer (Biolegend). Antibodies used for staining from Biolegend were as follows: CD45.1 PerCp-Cy5.5 (A20), CD45.2 Pacific Blue (104), CD3 AF488 (17A2), CD4 PE (RM4–4), CD11b BV605 (M1/70), CD19 PE-Cy7 (6D5), CD49b APC (DX5), CD25 PE-Cy5 (PC61), CD8a PE (53–6.7), Ter-119 PE, CD11b PE (M1/70), Gr-1 PE (RB6–8C5), CD3 PE (17A2), B220 PE (RA3–6B2), CD317 PE (927), CD172a APC (P84), CD11c AF700 (N418), CD304 PE (3E12), FOXP3 AF647 (150D), Helios AF488 (22F6), B220 FITC (RA3–6B2), CD8a BV510 (53–6.7). eBioscience antibodies used were as follows: CD117 APC (2B8), Sca-1 Pe-Cy7 (D7). Staining of intracellular markers was conducted with Biolegend True-Nuclear Transcription Factor Buffer Set as per manufacturer’s instructions. For live cell sorting, propidium iodide (MilliporeSigma) was used to determine viability. Cells were analyzed and/or sorted with a BD FACSAria II. Data were analyzed using FlowJo (10.7).
+ Open protocol
+ Expand
2

Multicolor Flow Cytometry Panel

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following antibodies were used: mouse lineage cocktail-PE (BioLegend, cat# 78035), mouse lineage cocktail-APC (R&D Systems, cat# FLC001A), c-Kit-FITC (BioLegend, cat# 161603), c-Kit-APC (BioLegend, cat# 135108), c-Kit-PE/Cy7 (BioLegend, cat# 105814), c-Kit-BV421 (BioLegend, cat# 135124), Sca-1-BV605 (BioLegend, cat# 108133), Sca-1-APC (eBioscience, cat# 17-5981-82), Sca-1-BV421 (BioLegend, cat# 108127), Sca-1-PerCP-Cy5.5 (eBioscience, cat# 45-5981-82), CD150-BV421 (BioLegend, cat# 115925), CD150-PE (eBioscience, cat# 12-1501-82), CD150-PE-Cy7 (BioLegend, cat# 115913), CD48-PE/Cy7 (eBioscience, cat# 25-0481-80), CD48-BV711 (BioLegend, cat# 103439), CD48-APC-Cy7 (BioLegend, cat# 103432),CD34-FITC (eBioscience, cat# 11-0341-82), CD135-PE-Cy5 (BioLegend, cat# 135311), CD135-APC (BioLegend, cat# 135310), CD45.1-PerCP-Cy5.5 (BioLegend, cat# 110727), CD45.2-BV421 (BioLegend, cat# 109831), CD45.2-FITC(eBioscience, cat# 11-0454-82), Gr1-PE (BioLegend, cat# 108407), CD11b-APC (BioLegend cat# 101211), CD4-PE (BioLegend,cat# 116005), CD8a-PE (BioLegend, cat# 100707), B220-APC (BioLegend, cat# 103211).
+ Open protocol
+ Expand
3

Multiparameter Flow Cytometry Analysis of Hematopoietic Reconstitution

Check if the same lab product or an alternative is used in the 5 most similar protocols
Gating strategies can be found in Supplemental Information (Figures S7 and S8). For analysis of mixed chimerism, cells were first stained with LIVE/DEAD Fixable Near-IR Dead Cell Stain Kit (ThermoFisher Scientific) and blocked with TruStain FcX anti-mouse (Biolegend) for 10 min on ice in Cell Stain Buffer (Biolegend). Antibodies used for staining from Biolegend were as follows: CD45.1 PerCp-Cy5.5 (A20), CD45.2 Pacific Blue (104), CD3 AF488 (17A2), CD4 PE (RM4–4), CD11b BV605 (M1/70), CD19 PE-Cy7 (6D5), CD49b APC (DX5), CD25 PE-Cy5 (PC61), CD8a PE (53–6.7), Ter-119 PE, CD11b PE (M1/70), Gr-1 PE (RB6–8C5), CD3 PE (17A2), B220 PE (RA3–6B2), CD317 PE (927), CD172a APC (P84), CD11c AF700 (N418), CD304 PE (3E12), FOXP3 AF647 (150D), Helios AF488 (22F6), B220 FITC (RA3–6B2), CD8a BV510 (53–6.7). eBioscience antibodies used were as follows: CD117 APC (2B8), Sca-1 Pe-Cy7 (D7). Staining of intracellular markers was conducted with Biolegend True-Nuclear Transcription Factor Buffer Set as per manufacturer’s instructions. For live cell sorting, propidium iodide (MilliporeSigma) was used to determine viability. Cells were analyzed and/or sorted with a BD FACSAria II. Data were analyzed using FlowJo (10.7).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!