The largest database of trusted experimental protocols

3 protocols using anti mouse alexa488

1

Isolation and Characterization of Uterine Vascular Smooth Muscle Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
UtVSMCs from pregnant rats (GD16) were isolated from the main uterine arteries using an enzymatic digestion method (24 (link)). Cell pellets were resuspended in DMEM (with 10% FBS and 100 U/mL penicillin, 100 µg/mL streptomycin), and cell solutions were distributed in culture dishes and kept in a humidified incubator at 37°C (5% CO2). Cell culture media was replaced every 48 h. Purity of utVSMCs was tested by immunocytochemistry for positive staining of VSMC marker smooth muscle actin (anti-α-smooth muscle actin, 1:400, Sigma Cat. No. A2547; secondary: anti-mouse Alexa 488, 1:500, Abcam, Cat. No. ab150113). Anti platelet endothelial cell adhesion molecule 1 (PECAM 1; CD31, 1:3,200, Cell Signaling, Cat. No. 3528S) was used as a negative control. Cultured utVSMCs were used at passage 2 to avoid genotypic and phenotypic drifts.
+ Open protocol
+ Expand
2

Functional Blocking of Leukocyte Adhesion

Check if the same lab product or an alternative is used in the 5 most similar protocols
Function blocking anti-human ICAM-1 (15.2) from Serotec (Raleigh, NC), anti-mouse ICAM-1mAb (YN1/1.7.4), anti-Ly-6G conjugated to Alexa 488 and anti-mouse MHC Class-I (W6/32) from eBioscience (San Diego, CA), anti-CD11b/CD18 mAb (CBRM1/29) purified in-house as previously described,59 (link) Rabbit anti-Akt and anti-β-catenin phospho forms from Cell Signaling (Danvers, MA), anti-Mouse-Alexa488 (Carlsbad, CA), anti-human MHC Class-I (1.B.548) and Rabbit anti-Ki67 from Abcam (Cambridge, MA), Isotype control IgG1 from BD Biosciences (San Jose, CA), HRP-conjugated anti-mouse and anti-rabbit IgGs from Jackson Immunoresearch (West Grove, PA). Click-iT® EdU Alexa Fluor® 488 Imaging Kit Molecular Probes (Eugene, Oregon), Akt inhibitor VIII (Billerica, Massachusetts, EMD Millipore), ABTS (2,2′-azinobis-3-ethylbenzothiazoline-6-sulfonic acid), L-mimosine, HBSS with Ca2+ and Mg2+ (HBSS+) and HBSS without Ca2+ and Mg2+ (HBSS-), DMEM including media supplements as well as chemotactic peptide fMLF, mouse IFNγ and TNFα from Sigma (St Louis, MO).
+ Open protocol
+ Expand
3

Functional Blocking of Leukocyte Adhesion

Check if the same lab product or an alternative is used in the 5 most similar protocols
Function blocking anti-human ICAM-1 (15.2) from Serotec (Raleigh, NC), anti-mouse ICAM-1mAb (YN1/1.7.4), anti-Ly-6G conjugated to Alexa 488 and anti-mouse MHC Class-I (W6/32) from eBioscience (San Diego, CA), anti-CD11b/CD18 mAb (CBRM1/29) purified in-house as previously described,59 (link) Rabbit anti-Akt and anti-β-catenin phospho forms from Cell Signaling (Danvers, MA), anti-Mouse-Alexa488 (Carlsbad, CA), anti-human MHC Class-I (1.B.548) and Rabbit anti-Ki67 from Abcam (Cambridge, MA), Isotype control IgG1 from BD Biosciences (San Jose, CA), HRP-conjugated anti-mouse and anti-rabbit IgGs from Jackson Immunoresearch (West Grove, PA). Click-iT® EdU Alexa Fluor® 488 Imaging Kit Molecular Probes (Eugene, Oregon), Akt inhibitor VIII (Billerica, Massachusetts, EMD Millipore), ABTS (2,2′-azinobis-3-ethylbenzothiazoline-6-sulfonic acid), L-mimosine, HBSS with Ca2+ and Mg2+ (HBSS+) and HBSS without Ca2+ and Mg2+ (HBSS-), DMEM including media supplements as well as chemotactic peptide fMLF, mouse IFNγ and TNFα from Sigma (St Louis, MO).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!