Surveyor lc

Manufactured by Thermo Fisher Scientific

The Surveyor LC is a high-performance liquid chromatography (HPLC) system designed for analytical and preparative applications. It is capable of delivering precise and reproducible mobile phase flow rates for efficient separation and purification of a wide range of chemical compounds. The Surveyor LC provides reliable performance and flexibility to meet the needs of diverse laboratory workflows.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using surveyor lc

1

Strong Cation Exchange Chromatography

Check if the same lab product or an alternative is used in the 5 most similar protocols
Strong cation exchange was carried out using a polysulfoethylaspartamide column (9.4 × 200 mm; PolyLC) on a Surveyor LC quaternary pump (Thermo Scientific; flow rate of 3.0 ml/min). The following gradient was used for separation: 0–2 min, 100% buffer A; 2–5 min, 0%–15% buffer B; 5–35 min, 15%–100% buffer B. Buffer B was held at 100% for 10 min. The column was washed extensively with buffer C and water prior to recalibration. Buffers were as follows: buffer A (5 mm KH2PO4, 30% acetonitrile (pH 2.65)), buffer B (5 mm KH2PO4, 30% acetonitrile, 350 mm KCl (pH 2.65)), buffer C (50 mm KH2PO4, 500 mm KCl (pH 7.5)). Samples were collected by hand and desalted via solid phase extraction.
+ Open protocol
+ Expand
2

In Vitro Release Kinetics of Fluorescent Ciprofloxacin from Contact Lenses

Check if the same lab product or an alternative is used in the 5 most similar protocols
The modified Comfilcon A lenses were placed into individual wells of a 24 well plate with 1 mL PBS in each well at room temperature. The PBS solution was replaced with fresh PBS every hour for up to 8 h or 15 h, or every ten minutes for 2 h or 6 h. The amount of fluorescent compound released into the collected PBS aliquots was quantified spectrophotometrically based on the above standard curve. The amount of F-Cip released into the collected PBS aliquots was quantified using LC-MS (LCQ Deca XP plus with Surveyor LC, Thermo Fisher, Waltham, MA) with electrospray ionization in positive ion mode. Samples (5 μL each) were loaded onto the analytical column at 200 μL/min (Kinetex XB-C18, 2.1 × 50 mm, 2.6 μm, Phenomenex) with the following gradient: 0-3 min, 10-75% (B); 3-7.5 min, 75-91% (B). The mobile phase consists of (A) water containing 0.1% formic acid and (B) acetonitrile containing 0.1% formic acid. Mass spectrometric parameters were as follows: 250 °C capillary temperature, 45 units sheath gas, 10 units aux gas and 4.5 kV spray voltage. Selective ion monitoring (SIM) was used for detecting F-Cip 1 and 2, and the quantification was based on the respective standard calibration curve. The detection limit for F-Cip 1 and 2 is approximately 1.5 pg based on S/N ratios.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!