The largest database of trusted experimental protocols

Quantigene 2.0 multiplex kit

Manufactured by Thermo Fisher Scientific

The Quantigene 2.0 multiplex kit is a laboratory equipment product from Thermo Fisher Scientific. It is designed for the quantitative measurement of multiple gene expression targets simultaneously in a single sample.

Automatically generated - may contain errors

2 protocols using quantigene 2.0 multiplex kit

1

Multiplex Gene and Protein Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
For gene array, corneas were processed using a magnetic bead-based Quantigene 2.0 multiplex kit (Affymetrix). Briefly, samples were lysed to extract RNA and incubated with specific target probes overnight. Signals were amplified with a hybridization technique, and detected using a luminex instrument (Biorad) after adding streptavidin with phycoerythrin as a substrate. For protein array, tissues were homogenized with a Tissuemiser (Fisher Scientific) in Tissue Protein Extraction Reagent (T-PER, Fisher Scientific) in the presence of 1x Calbiochem protease inhibitor cocktail set I (Millipore). Homogenates were centrifuged in a microcentrifuge at 10,000×g for 90 sec at 4° C, and the supernatants were evaluated for analyte content by multiplex (Millipore) or ELISA (R&D) assays.
+ Open protocol
+ Expand
2

Multiplex Gene and Protein Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
For gene array, corneas were processed using a magnetic bead-based Quantigene 2.0 multiplex kit (Affymetrix). Briefly, samples were lysed to extract RNA and incubated with specific target probes overnight. Signals were amplified with a hybridization technique, and detected using a luminex instrument (Biorad) after adding streptavidin with phycoerythrin as a substrate. For protein array, tissues were homogenized with a Tissuemiser (Fisher Scientific) in Tissue Protein Extraction Reagent (T-PER, Fisher Scientific) in the presence of 1x Calbiochem protease inhibitor cocktail set I (Millipore). Homogenates were centrifuged in a microcentrifuge at 10,000×g for 90 sec at 4° C, and the supernatants were evaluated for analyte content by multiplex (Millipore) or ELISA (R&D) assays.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!