Xcalibur 4.0 qual browser

Manufactured by Thermo Fisher Scientific
Sourced in Slovakia

The Xcalibur 4.0 Qual browser is a software application designed to provide a comprehensive user interface for accessing, analyzing, and managing data generated from Thermo Scientific mass spectrometry instruments. It offers a range of functions to facilitate the interpretation and presentation of qualitative analytical data.

Automatically generated - may contain errors

3 protocols using xcalibur 4.0 qual browser

1

Untargeted Sweat Metabolomics by LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Raw files generated by the Q Exactive HF instrument were analysed using the Compound Discoverer Software 3.1 (Thermo Fisher Scientific). Identified compounds were manually reviewed using Xcalibur 4.0 Qual browser and Freestyle (version 1.3.115.19) (both Thermo Fisher Scientific) and the obtained MS2 spectra were compared to reference spectra, which were retrieved from mzcloud (Copyright © 2013–2020 HighChem LLC, Slovakia). The match factor cut-off from mzcould was 80, while the mass tolerances were 5 and 10 ppm on MS1 and MS2 levels, respectively. Moreover, the identity of compounds suggested by Compound Discoverer was verified by analysing purchased standards using the same LC-MS method. The Tracefinder Software 4.1 (Thermo Fisher Scientific) was used for peak integration and calculation of peak areas. The generated batch table was exported and further processed with Microsoft Excel (version 1808), GraphPad Prism (version 6.07) and the Perseus software (version 1.6.12.0)70 (link), the letter being used for the principal component analysis. Untargeted metabolic profiling by mass spectrometry delivered more than 50000 reproducible sweat-specific features per analysis. Microsoft PowerPoint (version 1808) was used for creating figures.
+ Open protocol
+ Expand
2

Untargeted Metabolomics Data Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Raw files generated by the Q Exactive HF were searched in the Compound Discoverer Software 3.1 (Thermo Fisher Scientific) applying a user-defined workflow. All identified compounds with a match factor ≥ 80 were manually reviewed using Xcalibur 4.0 Qual browser (Thermo Fisher Scientific) and the obtained MS2 spectra were compared to reference spectra taken from mzcloud (Copyright © 2013–2020 HighChem LLC, Slovakia). A maximum retention time shift of 0.1 min was allowed and the mass tolerance was restricted to 10 ppm for MS1 and MS2. Identified compounds were also verified using purchased analytical standards applying the same LC–MS method. The Tracefinder Software 4.1 (Thermo Fisher Scientific) was used for peak integration and calculation of peak areas. Generated batch tables were exported and further process with Microsoft Excel, GraphPad Prism (for two-tailed, paired t-tests) and the Perseus [45 (link)] (for principal component analysis) software. ACD/Labs’ ChemSketch (Freeware) 2020.1.1 was used to draw structures.
+ Open protocol
+ Expand
3

Compound Identification and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Raw files generated by the Q Exactive HF instrument were analysed using the Compound Discoverer Software 3.1 (Thermo Fisher Scientific). Identified compounds were manually reviewed using Xcalibur 4.0 Qual browser (Thermo Fisher Scientific) and the obtained MS2 spectra were compared to reference spectra, which were retrieved from mzcloud (Copyright © 2013-2020 HighChem LLC, Slovakia). The match factor cut-off from mzcould was 80, while the mass tolerances were 5 and 10 ppm on MS1 and MS2 levels, respectively. Moreover, the identity of compounds suggested by Compound Discoverer was verified by analysing purchased standards using the same LC-MS method. The Tracefinder Software 4.1 (Thermo Fisher Scientific) was used for peak integration and calculation of peak areas. The generated batch table was exported and further processed with Microsoft Excel, GraphPad Prism and the Perseus software, 50 the letter being used for the principle component analysis.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!