Eagle bottom mount camera

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Eagle bottom mount camera is a high-performance imaging solution designed for microscopy applications. It features a large active image area, high resolution, and excellent low-light sensitivity to capture detailed and accurate images. The camera is intended to be mounted beneath the microscope stage to provide a direct view of the sample.

Automatically generated - may contain errors

4 protocols using eagle bottom mount camera

1

Cryo-TEM Specimen Preparation Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Specimens of cryo-TEM imaging were prepared by Vitrobot (FEI, Hillsboro, OR). The solutions were initially loaded on a copper grid with Lacey carbon film (Electron Microscopy Sciences, Hatfield, PA) in the controlled humidity chamber and were blotted by the filter papers that were mounted on the Vitrobot from both sides of the grid. This process engenders a thin film of solutions that adhere on the sample grid. The blotted samples were then transferred into liquid ethane and were stored in liquid nitrogen until further use. Sample imaging was conducted on a FEI Tecnai 12 TWIN electron microscope at 100 kV. The micrographs were acquired by a 16 bit 2K × 2K FEI Eagle bottom mount camera.
+ Open protocol
+ Expand
2

Transmission Electron Microscopy of Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
TEM and Cryo-TEM images were captured on an FEI Tecnai 12 TWIN Transmission Electron Microscope, operating at 100 kV for TEM and 80 kV for cryo-TEM. 25 μM TEM samples were pipetted onto a carbon-coated copper grid (Electron Microscopy Sciences, Hatfield, PA). Filter paper was used to wick away excess solution. 10uL of 2 wt% aqueous uranyl acetate was used to stain samples. For cryo-TEM, 25 μM samples were pipetted onto lacey carbon coated TEM grids (LC325-Cu, Electron Microscopy Sciences) pre-treated with plasma air to make the lacey carbon film hydrophilic. Samples were vitrified by plunging them into a liquid ethane reservoir precooled with liquid nitrogen. Both TEM and Cryo-TEM images were acquired with a 16 bit 2k × 2k FEI Eagle bottom mount camera (Hillsboro, OR). Images were processed with ImageJ (NIH, Bethesda, MD). Nanoparticle size was averages from three areas of view with more than 50 particles per image for TEM and 20 particles for Cryo-TEM. Bilayer thickness was averaged across three points along the circumference of the vesicle. Numbers are presented as averages ± 95% confidence interval.
+ Open protocol
+ Expand
3

Cryo-TEM Imaging of Nanoworms

Check if the same lab product or an alternative is used in the 5 most similar protocols
For cryo-TEM, 5 μM Nanoworm suspended in dPBS were evaluated. Lacey carbon film copper grids (300 mesh, Electron Microscopy Services, Hatfield, PA, USA) were pretreated with plasma air for 30 s to render the lacey carbon film hydrophilic. A 6 μL sample was applied on the grid using a Vitrobot (FEI, Hillsboro, OR, USA) that was maintained at 95% humidity. Following 1 min incubation, blotting was performed using Vitrobot preset parameters and the grid was immediately plunged into a liquid ethane reservoir precooled by liquid nitrogen. Grids were then transferred to a cryo-holder and cryo-transfer stage that were precooled with liquid nitrogen. A FEI Tecnai 12 Twin Transmission Electron Microscope, operating at 100 kV, was used to perform all imaging. The cryo-holder was maintained below −170 °C with liquid nitrogen to prevent the sublimation of vitreous water during the imaging process. All images were recorded with a 16-bit 2 K × 2 K FEI Eagle bottom mount camera (Hillsboro, OR, USA). The length and the width of Nanoworms were measured using ImageJ (v2.0.0, NIH, MD) based on the reference length presented in Fig. 1D.
+ Open protocol
+ Expand
4

Cryo-TEM Sample Preparation Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
6 μL of sample solution was placed on a holey carbon film supported on a TEM copper grid (Electron Microscopy Services, Hatfield, PA, USA). All the TEM grids used for cryo-TEM imaging were treated with plasma air to render the lacey carbon film hydrophilic. A thin film of the sample solution was produced using a Vitrobot with controlled humidity chamber (FEI). After loading of the sample solution, the lacey carbon grid was blotted using preset parameters and plunged instantly into a liquid ethane reservoir pre-cooled by liquid nitrogen. The vitrified samples were then transferred to a cryo-holder and cryo-transfer stage that was cooled by liquid nitrogen. Imaging was performed using a FEI Tecnai 12 TWIN Transmission Electron Microscope (100 kV) and images were recorded by a 16 bit 2K × 2K FEI Eagle bottom mount camera. To prevent sublimation of vitreous water, the cryo-holder temperature was maintained below −170 °C during the imaging process.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!