The largest database of trusted experimental protocols

Dclu00

Manufactured by R&D Systems
Sourced in United States

The DCLU00 is a laboratory instrument designed for the collection and analysis of liquid samples. The device features automated liquid handling capabilities, including the ability to aspirate, dispense, and mix liquids with precision. It is intended for use in a wide range of research and diagnostic applications that require accurate and reproducible liquid handling.

Automatically generated - may contain errors

5 protocols using dclu00

1

Plasma Clusterin Levels by ELISA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma clusterin levels were measured using enzyme-linked immunosorbent assay (ELISA) kits (DCLU00, R&D Systems, Minneapolis, MN, USA) according to the manufacturer's instructions. The minimum detectable concentrations of clusterin was 3.1 ng/ml. Blood samples of all the participants were measured on the same day.
+ Open protocol
+ Expand
2

Plasma and CSF Lipid Biomarkers Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma cholesterol (Roche), ApoA-I (Roche), ApoB (Roche), and ApoE (Kamiya) concentrations were assayed on a Cobas C311 (Roche) and plasma and CSF human serum albumin by ELISA (E88-129; Bethyl Laboratories, Inc.). CSF cholesterol and triglyceride phospholipid were determined by fluorescence assays (A12216 (Invitrogen) and MAK122 (Sigma-Aldrich), respectively). CSF ApoA-I (DAPA10 (R&D Systems, Inc.)), ApoB (ab108807 (Abcam)), ApoE (ab108813 (Abcam)), and ApoJ (DCLU00 (R&D Systems, Inc.)) were determined by ELISA.
+ Open protocol
+ Expand
3

Biomarker Profiling in Diabetic Patients

Check if the same lab product or an alternative is used in the 5 most similar protocols
All serum samples obtained from the control group participants and the patients were appropriately stored at −80 °C until assayed after separation from clotted blood by centrifugation for 10 min at 1200× g in 4 °C. MCP-1, activin-A, and clusterin concentrations were measured using commercially available sandwich ELISA kits (MCP-1: DCP00; activin-A: DAC00B; clusterin: DCLU00; R&D Systems, Minneapolis, MN, USA). The tests were performed according to the manufacturer’s recommended protocols.
The participants’ lipid profiles (total serum cholesterol, high-density lipoprotein (HDL), low-density lipoprotein (LDL), triglyceride, creatinine levels, and hemoglobin A1c (HbA1c)) were also determined using an automated analyzer (ADVIA® 2400 Chemistry System, Siemens, Athens, Greece). Epidemiological and clinical data including the age, duration of diabetes, glucose control expressed as HbA1c concentrations, and severity of obesity, were documented using the patients’ medical records. Estimated glomerular filtration rate (eGFR) was calculated using the revised bedside Schwartz formula, as indicated by the kidney disease improving global outcomes (KDIGO) guidelines [22 (link)].
+ Open protocol
+ Expand
4

Quantification of CSF Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
CSF Aβ42 was measured by a sandwich ELISA system using 6E10 as a capture antibody and alkaline phosphatase (AP)-conjugated 12F4 as a detection antibody. A 96-well black plate (Corning) was coated with the 6E10 monoclonal antibody at the concentration of 2 µg/ml in 0.05 M carbonate-bicarbonate buffer, pH 9.6, incubated overnight at 4°C with shaking, washed with PBS containing 0.05% Tween 20 and blocked with PBS containing 3% bovine serum albumin (BSA) for at least 24 hr at 4°C with mixing. CSF was diluted at 1∶4 with PBS containing 3% BSA. Diluted samples and a standard series of synthetic Aβ42 peptide (American Peptide Company) were incubated in triplicates with AP-conjugated detection antibody at 4°C overnight with shaking. After incubation, plates were washed and incubated with CDP-Star chemiluminescent substrate (Applied Biosystems) at RT for 20 min. The chemiluminescence was measured with an EnVision plate reader (Perkin Elmer). CSF total Tau was measured with INNOTEST hTAU Ag (Innogenetics) according to manufacturers' instructions. CSF clusterin (1∶200 dilution) was measured using a human clusterin ELISA kit (DCLU00, R&D Systems) according to manufactures' instructions.
+ Open protocol
+ Expand
5

Serum Clusterin Levels in Patients

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fasting blood samples were collected from all participants after overnight fasting for 8–10 h before surgery. Serum clusterin levels were measured using a sandwich enzyme-linked immunosorbent assay (ELISA; DCLU00, R&D Systems). Serum samples were tested after a 7600-fold dilution. The intra- and inter-assay evaluation results were <3.45 and <7.33%, respectively.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!