6230b lc tofms

Manufactured by Agilent Technologies

The 6230B LC-TOFMS is a liquid chromatography-time of flight mass spectrometer (LC-TOFMS) manufactured by Agilent Technologies. It is a high-resolution mass spectrometry system designed for accurate mass measurements and qualitative analysis of complex samples.

Automatically generated - may contain errors

2 protocols using 6230b lc tofms

1

Glycoprotein Characterization by LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH of the samples was set to 8.0 with the addition of 100 mM Tris. HCl and digestion with PNGase (Roche, Basel, Switzerland) were followed overnight at 37 °C for deglycosylation. Reduction was performed with 1.5 mM dithiothreitol (DTT) at 37 °C for 45 min, and samples were then analyzed immediately. Two µg of the samples were directly injected into an LC–ESI–MS system (LC: 1290 Infinity II UPLC, Agilent Technologies, Santa Clara, CA, USA). A gradient from 15 to 80% acetonitrile in 0.1% formic acid (using a BioResolve column (2.1 × 5 mm), Waters, Milford, MA, USA) at a flow rate of 400 μL/min was applied (9 min gradient time). Detection was performed with a Q-TOF instrument (6230B LC-TOFMS, Agilent Technologies) equipped with the Jetstream ESI source in positive ion, MS mode (range: 100–3200 Da). Instrument calibration was performed using an ESI calibration mixture (Agilent Technologies). Data were processed using MassHunter BioConfirm B.08.00 (Agilent Technologies), and the spectrum was deconvoluted with the MaxEnt algorithm.
+ Open protocol
+ Expand
2

Glycoprotein Characterization by LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH of the samples was set to 8.0 with the addition of 100 mM Tris. HCl and digestion with PNGase (Roche, Basel, Switzerland) were followed overnight at 37 °C for deglycosylation. Reduction was performed with 1.5 mM dithiothreitol (DTT) at 37 °C for 45 min, and samples were then analyzed immediately. Two µg of the samples were directly injected into an LC–ESI–MS system (LC: 1290 Infinity II UPLC, Agilent Technologies, Santa Clara, CA, USA). A gradient from 15 to 80% acetonitrile in 0.1% formic acid (using a BioResolve column (2.1 × 5 mm), Waters, Milford, MA, USA) at a flow rate of 400 μL/min was applied (9 min gradient time). Detection was performed with a Q-TOF instrument (6230B LC-TOFMS, Agilent Technologies) equipped with the Jetstream ESI source in positive ion, MS mode (range: 100–3200 Da). Instrument calibration was performed using an ESI calibration mixture (Agilent Technologies). Data were processed using MassHunter BioConfirm B.08.00 (Agilent Technologies), and the spectrum was deconvoluted with the MaxEnt algorithm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!