1

Characterization of Organic Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the chemicals were used as acquired. All of the chemicals consumed were purchased from an international chemical supplier. The melting point was determined using a Stuart Scientific SMP3, version 5.0, melting point equipment (Bibby Scientific Limited, Staffordshire, UK), which was reported as uncorrected, on a clean Thermo Scientific NICOLE iS50 FT-IR spectrometer (Madison, WI, USA). Using TMS as an internal standard, the 1H, and 13C spectra were captured using Bruker 850 MHz equipment in a CDCl3. Chemical shifts are displayed in ppm, while coupling constants are given in hertz. Aluminum sheets covered with silica gel (Type 60 GF254, Merck, Darmstadt, Germany) were used for TLC, and the spots were found by exposing the sheets to UV light at either 254 or 360 nanometers. A PerkinElmer 2400 Series II Elemental CHN analyzer was used to perform elemental analyses. MoKa (k = 0.71073A) radiation was used to collect the single crystal X-ray data set for 2a on the Bruker Kappa X8 APPEX II diffractometer. The scan area was 2.22° to 33.00°.
+ Open protocol
+ Expand
2

Attenuated Total Reflectance FT-IR Spectroscopy

Check if the same lab product or an alternative is used in the 5 most similar protocols
FT-IR spectra were recorded in attenuated total reflectance (ATR) mode with 4 cm -1 resolution in the range of 400-4000 cm -1 using a Nicole IS50 FT-IR Spectrometer (Thermo Scientific, USA). Briefly, the sample was placed on the diamond crystal and consistent contact between the crystal and the sample was achieved with the gripper plate. The measurement was taken 16 times for each spectrum and their average was used for plotting.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!