The largest database of trusted experimental protocols

Deuterated methanol cd3od

Manufactured by Merck Group
Sourced in Germany, United States

Deuterated methanol (CD3OD) is a stable isotope-labeled chemical compound used in various analytical and research applications. It is a colorless, volatile liquid with a chemical formula of CD3OD. Deuterated methanol is primarily used as a solvent and reagent in nuclear magnetic resonance (NMR) spectroscopy, mass spectrometry, and other analytical techniques.

Automatically generated - may contain errors

10 protocols using deuterated methanol cd3od

1

Metabolic profiling of rat diabetes

Check if the same lab product or an alternative is used in the 5 most similar protocols
3-Trimethylsilylpropionic acid (TSP) and Streptozotocin (STZ) were obtained from Sigma-Aldrich (St. Louis, USA). Deuterium oxide (D2O, 99.9%), deuterated methanol (CD3OD, 99.9%), potassium dihydrogren phosphate, deuterated sodium hydroxide and sodium azide were purchased from Merck (Darmstadt, Germany). The normal rat chow feed was purchased from Specialty feeds (Glen Forrest, Australia).
+ Open protocol
+ Expand
2

NMR and LCMS Analysis of Rat Chow

Check if the same lab product or an alternative is used in the 5 most similar protocols
All rats consumed the normal rat chow from Specialty Feeds (Glen Forrest, Australia). The phosphate buffer saline (PBS), lipopolysaccharide (LPS) derived from Escherichia coli 026: B6, and dextromethorphan hydrobromide (DXM) were obtained from Sigma Aldrich (St. Louis, United States). The NMR analysis used solvents in deuterated form, including deuterium oxide (D2O, 99.9%), deuterated methanol (CD3OD, 99.9%), deuterated sodium hydroxide and potassium dihydrogen phosphate were purchased from Merck (Darmstadt, Germany), and 3-Trimethylsilyl propionic acid (TSP) was purchased from Sigma Aldrich (St. Louis, United States). The LCMS analysis acquired LC-MS grade methanol, acetonitrile, water, and 0.1% formic acid from Merck (Darmstadt, Germany).
+ Open protocol
+ Expand
3

Profiling and Authenticating Lonicerae Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
A total of 100 batches of LJF and LF samples were collected from all over China, including 77 batches of cultivated Lonicerae japonicae flos (cLJF) with different processing methods and different origins, 10 batches of wild Lonicerae japonicae flos (wLJF), and 13 batches of Lonicerae flos (LF). The detailed sample information is shown in Table 3. All the samples were authenticated by Chief Pharmacist Ji Zhang, who is the former Director of the Traditional Chinese Medicine Herbarium at the China National Institute for Food and Drug Control. Voucher samples were preserved and stored in the cold sample room of Shenzhen Institute for Drug Control.
Deuterated methanol (CD3OD, purity ≥ 99.8%) containing 0.05% (v/v) TMS was purchased from Merck. Secologanoside (purity 99.28%) analytical standard was acquired from Sichuan Weikeqi Biological Technology Co., Ltd. Secoxyloganin (Chengdu, China) (purity 98.93%) analytical standard was acquired from Shanghai Hongyong Biological Technology Co., Ltd. Macranthoidin A (Shanghai, China) (purity 100.0%) was acquired from Standard Technology Co., Ltd. (Shanghai, China). Macranthoidin B (purity 96.1%), Dipsacoside B (purity 96.8%) and Sweroside (purity 98.3%) were purchased from the National Institute for Food and Drug Control (Beijing, China). All of the other chemicals used in this study were of analytical grade.
+ Open protocol
+ Expand
4

Chromatographic Separation and Identification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The solvents, dichloromethane, ethyl acetate, acetonitrile, ethanol and methanol were of HPLC grade, purchased from Fisher Chemical (Fisher Scientific, Loughborough, Leics, UK). Silica gel 0.040–0.063 mm, TLC (20 × 20 cm) of normal and reverse phase, deuterated methanol (CD3OD) and deuterated chloroform (CDCl3) were purchased from Merck KGaA (Darmstadt, Germany); olive oil was extra virgin oil “ALTIS” (ELAIS).
+ Open protocol
+ Expand
5

Profiling and Authenticating Lonicerae Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
A total of 100 batches of LJF and LF samples were collected from all over China, including 77 batches of cultivated Lonicerae japonicae flos (cLJF) with different processing methods and different origins, 10 batches of wild Lonicerae japonicae flos (wLJF), and 13 batches of Lonicerae flos (LF). The detailed sample information is shown in Table 3. All the samples were authenticated by Chief Pharmacist Ji Zhang, who is the former Director of the Traditional Chinese Medicine Herbarium at the China National Institute for Food and Drug Control. Voucher samples were preserved and stored in the cold sample room of Shenzhen Institute for Drug Control.
Deuterated methanol (CD3OD, purity ≥ 99.8%) containing 0.05% (v/v) TMS was purchased from Merck. Secologanoside (purity 99.28%) analytical standard was acquired from Sichuan Weikeqi Biological Technology Co., Ltd. Secoxyloganin (Chengdu, China) (purity 98.93%) analytical standard was acquired from Shanghai Hongyong Biological Technology Co., Ltd. Macranthoidin A (Shanghai, China) (purity 100.0%) was acquired from Standard Technology Co., Ltd. (Shanghai, China). Macranthoidin B (purity 96.1%), Dipsacoside B (purity 96.8%) and Sweroside (purity 98.3%) were purchased from the National Institute for Food and Drug Control (Beijing, China). All of the other chemicals used in this study were of analytical grade.
+ Open protocol
+ Expand
6

Antioxidant Compounds Isolation and Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
2,2-Diphenyl-1-picrylhydrazyl (DPPH), Folin-Ciocalteu phenol reagent, trifluoroacetic acid (TFA), sulfuric acid, sodium carbonate, vanillin, gallic acid, l-ascorbic acid, (+)-catechin, deuterium oxide (D2O), and deuterated methanol (CD3OD) were purchased from Sigma–Aldrich (St. Louis, MO, USA). The Purospher STAR RP-18e column (4.0 mm i.d. × 250 mm, 5 μm) was purchased from Merck (Darmstadt, Germany). Methanol and acetonitrile were LiChrosolv and were purchased from Merck. Diaion HP-20 gel (Mitsubishi Chemical Industry, Tokyo, Japan), Sephadex LH-20 gel (GE Healthcare Biosciences, Uppsala, Sweden), LiChroprep RP-18 gel (40–63 μm, Merck), MCI CHP20P gel (Supelco, Bellefonte, PA, USA) and an Oasis HLB cartridge (12 mL, 500 mg, Waters, Milford, MA, USA) were used for the purification and isolation processes. Polyvinylidene difluoride (PVDF) 0.45-μm 13 mm syringe filters was purchased from IT’S Science Corporation (Taipei, Taiwan).
+ Open protocol
+ Expand
7

Synthesis and Characterization of Polymeric Biomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dimethyl acrylamide (DMAm, 99 %; Sigma Aldrich 274135), Acrylic Acid (AA, 99 %; Sigma Aldrich 147230), (Methacryloyloxy)ethyl] trimethylammonium chloride (QDMAEMA, 75 % in H2O; Sigma Aldrich 408107), (Methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide (DMAPS, 95 %; Sigma Aldrich 537284), 4,4′-azobis(4-cyanovaleric acid) (ACVA, 99%; Sigma Aldrich 11590), 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC, 98%; Sigma Aldrich 341006), deuterated methanol (CD3OD, 99.8%; Sigma Aldrich 151947-10G-GL) and deuterium oxide (D2O, 99.9%; Sigma Aldrich 151882) were purchased from Sigma Aldrich (UK). DAAm (99%) was purchased from Alfa Aesar (UK; A15940.30). 4,4-Difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-propionic acyl hydrazide (BODIPY FL, 99 %) was purchased from ThermoFisher Scientific (UK; D2371). 4-((((2-Carboxyethyl)thio)carbonothioyl)thio)−4-cyanopentanoic acid (BM1433, 95%) was purchased from Boron Molecular (USA; BM1433).
For protoplast preparation, cellulase “Onozuka RS” was purchased from Melford biolaboratories (Duchefa; C8003.0005) and pectolyase from Sigma Aldrich (P3026).
+ Open protocol
+ Expand
8

Analytical Solvent Extraction and Chromatography

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical-grade solvents, including n-hexane, chloroform, and methanol, were used for the extraction and isolation procedures. The MTT reagent (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), HPLC-grade methanol, and deuterated methanol (CD3OD) were purchased from Sigma-Aldrich (Merck KGaA, Darmstadt, Germany). Cerium sulphate, used in the study, was also obtained from Sigma-Aldrich. HPLC-grade water with a resistivity of 18 MΩ was prepared using a Milli-Q50 purification system from Millipore Corp. (Bedford, MA, USA). The Sephadex LH-20 resin employed in the chromatography procedure was purchased from Supelco (Merck KGaA, Darmstadt, Germany). Furthermore, dimethyl sulfoxide (DMSO), used for solubilizing the extract and molecules during bioassays, was obtained from VWR Chemicals (VWR International Srl, Milano, Italy).
+ Open protocol
+ Expand
9

Analytical Reagents and Solvents Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals and reagents used, including the solvents, were of analytical grade. The solvents were distilled before use. Acetone (Ref.: 20066.330), methanol (MeOH, Ref.: 20903.368), sulfuric acid (H2SO4, Ref.: 470302.872), dichlorometane (DCM, Ref.: 23367.321), and dimethyl sulfoxide (DMSO, Ref.: 23486.322) were from VWR Chemicals). Other materials were hexane (Hex, Fisher Scientific, Ref.: H/0355/21), ethyl acetate (EtOAc; LabChem, Ref.: MP013-9025), trifluoroacetic acid (Sigma-Aldrich, Ref.: 8082600101), sand pure 40–100 mesh (Acrōs organics, Ref.: 370942500); MeOH HPLC grade (Fisher Scientific, Ref.: M/4056/17); ACN HPLC grade (Honeywell, Ref.: 608-001-00-3), K2Cr2O7 (Labonal S.A., Ref.: 2635), and bidistillated water. Furthermore, filter paper (Whatman No. 5 paper, Inc., Clifton, NJ, USA), deuterated-chloroform 99.8 + 0.03% TMS (CDCl3, Deutero.de-Rotoquímica, Ref.: 00405), and deuterated methanol (CD3OD, Sigma Aldrich, Ref.: 1.06028) were used.
+ Open protocol
+ Expand
10

Standardized Compound Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standards (gallic acid, lycorine, galanthamine, tyramine, tyrosine, α-glucose, β-glucose, sucrose, alanine, valine) are purchased by Sigma Aldrich (Sigma-Aldrich, St. Quentin Fallavier, France). All solvents used are analytical profile grade, deuterated methanol (CD3OD), 3-(trimethylsilyl)-1-propanesulfonic acid sodium salt (DSS sodium salt), sodium deuteroxide solution (NaOD) 40 wt.% in deuterium oxide (D2O), 99.5 atom % D, ammonium hydroxide solution (NH4OH) containing ≥25% NH3 basis, were purchased from Sigma Aldrich (Sigma-Aldrich, St. Quentin Fallavier, France). All chemicals for in vitro culture are listed in the article Saliba et al. [29 (link)]. SCX cation exchanger column are purchased by Interchim® (Interchim, Montluçon, France).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists