The largest database of trusted experimental protocols

Vf 7501

Manufactured by Keyence

The VF-7501 is a digital microscope manufactured by Keyence. It features a high-resolution camera and optical system to capture detailed images and video of small objects or samples. The device is designed for laboratory and industrial applications where precise visual inspection and measurement are required.

Automatically generated - may contain errors

2 protocols using vf 7501

1

Wrinkle Pattern Analysis and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Static wrinkle patterns were recorded with a 3D laser scanning confocal microscope (VK-X1000, KEYENCE). The dynamic wrinkle pattern elimination/reappearance process was recorded with a profile measurement microscope (VF-7501, KEYENCE). The Young's modulus of the top film was measured by atomic force microscopy nanomechanical mapping (Dimension Icon & FastScan Bio, Bruker), where the oscillation frequency of the Z-piezo was 1.0 kHz and the peak force amplitude was set at 150 nm. The samples were scanned using Olympus microcantilevers with a spring constant of 3 N/m. The NIR light was produced by a laser diode controller (λ = 808 nm; LE-LS-808-1000TFCB, LEO Photonics). 1H NMR spectra were measured on a Varian Mercury Plus spectrometer (400 MHz) with deuterated chloroform (CDCl3) as the solvent and tetramethylsilane as an internal standard at room temperature.
+ Open protocol
+ Expand
2

Characterization of PAN Polymers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Surface patterns and their erasure/regeneration process were recorded by a profile measurement microscope (VF-7501, KEYENCE). AFM was also carried out to measure wrinkles in tapping mode by using silicon cantilevers with a force constant of 40 N/mv (E-Sweep, Seiko Instruments Inc.). The laser source used in the experiments was a laser diode controller (λ = 808 nm; LE-LS-808-1000TFCB, LEO Photonics). 1H nuclear magnetic resonance spectra were recorded on a Varian Mercury Plus spectrometer (400 MHz) with deuterated chloroform (CDCl3) and dimethyl sulfoxide-d6 as the solvent and tetramethylsilane as an internal standard at room temperature. The cross-linking dynamics of PAN was recorded via a TU-1091 spectrophotometer (Persee). Average molecular weight was measured by gel permeation chromatography (LC-20A, Shimadzu) using THF as an eluent.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!