The largest database of trusted experimental protocols

2 protocols using macerozyme r 10

1

Comprehensive Chemical Inventory for Research

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ethanol, mEthanol, chloroform, glacial acetic acid, HNO3, H2O2, Na2HPO4, NaH2PO4, AgNO3, Na2CO3 and sodium dodecyl sulphate (SDS) were purchased from Merck, Bengaluru, India. Bovine serum albumin and chitosan powder were purchased from Sisco Research Laboratories, Chandigarh, India. Glutaraldehyde was purchased from TCI Chemicals, Chandigarh, India. A Spurr resin kit and OsO4 were purchased from Electron Microscopy Sciences, Delhi, India. Uranyl acetate was purchased from LobaChemie, India. CuCl, selenourea, oleylamine, citric acid, sodium citrate monobasic, lead citrate, Laemmli buffer, ammonium persulfate, trizma base, tetramethylethylenediamine (TEMED), acrylamide, N,N′- methylenebis(acrylamide), 3-(4,5-dimethythiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT), KOH, phenylmethylsulfonyl fluoride (PMSF) cocktail, KH2PO4, K2HPO4, glycerol, and formaldehyde were purchased from Sigma-Aldrich, Bengaluru, India. Bradford reagent, macerozyme R-10, 1X phosphate buffer saline (PBS), sodium thiosulfate, and ascorbate were purchased from HiMedia, Mumbai, India. Rehydration buffer, IPG strips of pH range 3–10, a ReadyPrep 2D starter kit equilibration buffer I and II, and a ReadyPrep 2D clean-up kit was purchased from Bio-Rad, Gurugram, India. A precision plus protein kaleidoscope prestained protein ladder was purchased from Bio-Rad.
+ Open protocol
+ Expand
2

Identification of Clinical Bacterial Cultures

Check if the same lab product or an alternative is used in the 5 most similar protocols
Macerating enzymes, Macerozyme R-10, Nutrient agar, Blood agar, Chocolate agar and MacConkey agar, Mueller–Hinton (MH) agar and potato dextrose agar (PDA) were purchased from Hi-Media Laboratories Pvt. Ltd. Mumbai, India. Silver nitrate (AgNO3) was acquired from S.D. Fine-Chem. Ltd. Mumbai, India. Throughout the experiment, MiliQ (Millipore®) water was used for solutions preparation. The antibiotics sensitivity tests were verified using antibiotics disc purchased from Hi-Media Laboratories Pvt. Ltd. Mumbai, India. The identification of clinical cultures was carried out by VITEK®2 system (Biomerieux Inc. Hazelwood, Mo.) at Anand Laboratory, Surat, India.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!