Water e2695 series hplc system

Manufactured by Waters Corporation
Sourced in United States

The Waters e2695 series HPLC system is a high-performance liquid chromatography (HPLC) instrument designed for laboratory use. It is a modular system that includes a solvent delivery system, autosampler, column oven, and a variety of detectors. The e2695 series is capable of performing a range of HPLC analyses and is suitable for various applications that require precise separation, identification, and quantification of chemical compounds.

Automatically generated - may contain errors

2 protocols using water e2695 series hplc system

1

HPLC Analysis of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The contents of calycosin and calycosin-7-O-β-D-glucoside from A. membranaceus extract (A extract) and lithospermic acid from L. erythrorhizon extract (L extract) were measured by HPLC-DAD as active compounds of each plant sample. For HPLC analysis, a YMC ODS-AM (4.6 × 250 mm, 5 μm) column was used at 30 °C with 0.1% formic acid and acetonitrile as the gradient system of the mobile phase in Water e2695 series HPLC system (Waters Corporation, Milford, MA, USA). The mobile phase was maintained at 5% acetonitrile for 3 min, increased to 20% for 3 min and then increased to 28% for 25 min. Then, elution was performed by increasing the mobile phase to 100% acetonitrile for 4 min. The flow rate was 1 ml/min, and the absorbance of the UV detector was measured at a wavelength of 254 nm.
+ Open protocol
+ Expand
2

HPLC Analysis of Astragalus membranaceus

Check if the same lab product or an alternative is used in the 5 most similar protocols
Based on Park et al.’s paper [34 (link)], the profiling of the extract of the dried root of Astragalus membranaceus was analyzed using HPLC. In brief, a YMC ODS-AM (4.6 × 250 mm, 5 μm) column was applied at 30 °C with 0.1% formic acid and acetonitrile as the gradient system of the mobile phase under the Water e2695 series HPLC system (Waters Corporation, Milford, MA, USA). The mobile phase was maintained in 5% acetonitrile for 3 min and increased to 20% for 3 min, and then, up to 28% for 25 min. Then, elution was carried out by increasing the mobile phase to 100% acetonitrile for 4 min with a flow rate of 1 mL/min. The absorbance of the UV detector was measured at a wavelength of 254 nm compared to standard chemicals such as calycosin (99%) and calycosin-7-O-β-D-glucoside (99%) with high purity from ChemFaces (Wuhan, China) and Sigma-Aldrich (St. Louis, MO, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!