The largest database of trusted experimental protocols

Agilent 6220 esi tof ms instrument

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 6220 ESI-TOF MS instrument is a high-resolution, accurate-mass time-of-flight mass spectrometer that utilizes electrospray ionization (ESI) as the ion source. The instrument is designed to provide precise mass measurements for the identification and characterization of molecular compounds.

Automatically generated - may contain errors

3 protocols using agilent 6220 esi tof ms instrument

1

Synthesis and Characterization of Fluorinated Amino Acids

Check if the same lab product or an alternative is used in the 5 most similar protocols
The
SAPs were prepared according to standard microwave-assisted SPPS and
purification protocols recently published by Koksch and co-workers.18 (link) The synthesis of the fluorinated amino acids
MfeGly, DfeGly, and TfeGly is described in the Supporting Information, plus the relevant NMR spectra (Figures S1–S6). High-resolution mass spectrometry
(HRMS) spectra were recorded on an Agilent 6220 ESI-TOF MS instrument
(Agilent Technologies, Santa Clara, CA, USA), and MassHunter Workstation
software version B.02.00 (Agilent Technologies, Santa Clara, CA, USA)
was used for data analysis. Unless otherwise stated, all other compounds
were obtained from Merck (Arklow, Ireland). The API 20E strip was
obtained from Biomerieux. The enzymes β-trypsin (pancreas),
elastase (pancreas), proteinase K (Tritirachium album), and bromelain (pineapple) were obtained from Sigma-Aldrich (Steinheim,
Germany).
+ Open protocol
+ Expand
2

Characterization of Fluorinated Amino Acids

Check if the same lab product or an alternative is used in the 5 most similar protocols

1H, 13C and 19F NMR spectra (Figures S1–S12) were recorded at room temperature using a JEOL ECX 400, a JEOL ECP 500 (JEOL, Tokyo, Japan) or a Bruker AVANCE III 700 (700 MHz, Bruker). Chemical shifts δ are reported in ppm with the solvent resonance as the internal standard (CDCl3=7.26 ppm, CD3OD=3.31 ppm). HRMS were determined on an Agilent 6220 ESI‐TOF MS instrument (Agilent Technologies). For analysis, the MassHunter Workstation Software VersionB.02.00 (Agilent Technologies) was used. Fmoc‐L‐amino acids were purchased from ORPEGEN Peptide Chemicals GmbH (Heidelberg, Germany). Fluorinated Fmoc‐L‐amino acids were purchased from commercial sources as follows:Fmoc‐[4F]Phe‐OH (VWR, Darmstadt, Germany), Fmoc‐[3.5F]Phe‐OH (ABCR, Karlsruhe, Germany), Fmoc‐[2.3.4.5.6F]Phe‐OH (Oxchem, Wood Dale, USA). Fmoc‐[2.3.4.5.6F][4I]Phe‐OH was kindly provided by Prof. Dr. Pierangelo Metrangolo. Fmoc‐[2.3.4.5.6F]Phe‐OH was synthesized according to literature.[19c]
+ Open protocol
+ Expand
3

Characterization of Fluorinated Amino Acids

Check if the same lab product or an alternative is used in the 5 most similar protocols
General methods
1 H-, 13 C-and 19 F-NMR spectra (see ESI †) were recorded at room temperature using a JEOL ECX 400 (JEOL, Tokyo, Japan), a JEOL ECP 500 (JEOL, Tokyo, Japan) or a Bruker AVANCE III 700 (700 MHz, BRUKER, Billerica, MA, USA). Chemical shifts δ are reported in ppm with the solvent resonance (MeOH-d 4 ) as the internal standard. HRMS were determined on an Agilent 6220 ESI-TOF MS instrument (Agilent Technologies, Santa Clara, CA, USA). For analysis, the MassHunter Workstation Software Version B.02.00 (Agilent Technologies, Santa Clara, CA, USA) was used. IR Spectra were recorded on an ALPHA II FT-IR spectrometer (Bruker, USA). All NMR and IR spectra were evaluated by using Mnova/Mestrenova (Mestrelab Research, CA, USA). Elemental analysis was proceeded by use of an VARIO EL elemental analyzer (Elementar Analysensysteme GmbH, Langenselbold, Germany). All essential data for compound characterization is placed within the ESI. † All chemicals were purchased from commercial sources (Merck, Sigma-Aldrich, VWR, Fluorochem) and used without further purification. The Fmoc-protected fluorinated amino acid TfeGly was synthesised according to literature (see ESI, † chapter "Gram scale synthesis and characterization of fluorinated amino acid Fmoc-TfeGly-OH"). MfeGly and DfeGly were synthesised by Suvrat Chowdhary and Thomas Hohmann.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!