Check if the same lab product or an alternative is used in the 5 most similar protocols
The HPLC gradient elution analysis was performed on Merck-Hitachi LaChrom Elite System (Merck, Darmstadt, Germany) with diode array detector L-2455, thermostat L-2300, pump L-2130 and autosampler L-2200 with the Kinetex RP18 (5 μm, 150 × 4.6 mm) chromatographic column (Phenomenex, Torrance, CA, USA) as stationary phase. The mobile phase was consisted of methanol-water-0.1% formic acid (gradient 5–100% (v/v) of methanol) at 30 °C and the run time was 60 min. The analysis was performed with the detection wavelength 280 nm, the sample injection volume was 10 μL and the flow rate was set to 1.0 mL min−1. Methanol Chromasolv for HPLC was purchased from Sigma-Aldrich (St. Louis, MO, USA) and formic acid from Polish Reagents (Polish Reagents, Gliwice, Poland); double-distilled water was used.
+ Open protocol
+ Expand
2

HPLC-UV-MS Quantification of mABA Labeled Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The concentration of the solutions of mABA-labeled standard and of the binary mixtures was determined by HPLC-UV-MS using the UV signal at 254 nm. Separation was performed on a RP-C18-column (Phenomenex Kinetex RP18, 100 × 2.1 mm, 2.6 μm) at 40 °C: flow rate, 0.2 mL min−1; eluent, H2O + 1% HOAc (A) and ACN + 1% HOAc (B); t = 0, 90% A and 10% B; linear gradient to 20% A and 80% B in 30 min; and injection volume, 3 μL (COS standards) and 8 μL (standard binary mixtures), n = 6. Quantification was based on an external calibration with mABA-labeled 2,3,6-tri-O-methyl glucose standard (0.38–3.82 ∙ 10−4 M). For MS parameter, see chapter Instrumentation.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!