Water Quality Analysis Methods

Check if the same lab product or an alternative is used in the 5 most similar protocols
Water quality parameters (i.e., temperature, pH, conductivity, and dissolved oxygen) were measured using the Orion Star A325 pH/conductivity portable multiparameter meter (Thermo Scientific; catalog no. STARA3250). Total chlorine was measured using U.S. Environmental Protection Agency (U.S. EPA)-approved Hach method 8167 with DPD total chlorine reagent powder pillows (Hach; catalog no. 2105669). Reactive orthophosphate was measured using U.S. EPA-approved Hach method 8048 with PhosVer 3 phosphate reagent powder pillows (Hach; catalog no. 2106028). Nitrogen species, including ammonium, nitrate, and nitrite were measured using the nitrogen-ammonia reagent set (method 10023; Hach; catalog no. 2604545), NitraVer X nitrogen-nitrate reagent set (method 10020; Hach; catalog no. 2605345), and NitriVer 3 TNT reagent set (method 10019; catalog no. 2608345), respectively. All Hach measurements were performed in triplicate on the DR1900 portable spectrophotometer (Hach; catalog no. DR190001H) (Table S1).
+ Open protocol
+ Expand
2

Water Quality Analysis Methods

Check if the same lab product or an alternative is used in the 5 most similar protocols
Water quality parameters (i.e., temperature, pH, conductivity, and dissolved oxygen) were measured using the Orion Star A325 pH/conductivity portable multiparameter meter (Thermo Scientific; catalog no. STARA3250). Total chlorine was measured using U.S. Environmental Protection Agency (U.S. EPA)-approved Hach method 8167 with DPD total chlorine reagent powder pillows (Hach; catalog no. 2105669). Reactive orthophosphate was measured using U.S. EPA-approved Hach method 8048 with PhosVer 3 phosphate reagent powder pillows (Hach; catalog no. 2106028). Nitrogen species, including ammonium, nitrate, and nitrite were measured using the nitrogen-ammonia reagent set (method 10023; Hach; catalog no. 2604545), NitraVer X nitrogen-nitrate reagent set (method 10020; Hach; catalog no. 2605345), and NitriVer 3 TNT reagent set (method 10019; catalog no. 2608345), respectively. All Hach measurements were performed in triplicate on the DR1900 portable spectrophotometer (Hach; catalog no. DR190001H) (Table S1).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!