The largest database of trusted experimental protocols

5 protocols using pipette gun

1

Comprehensive Biological Techniques Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Epoch microplate reader (Biotek, Winooski, VT, United States); Small desktop refrigerated centrifuge, Liquid nitrogen storage tank (Thermo Fisher Scientific, Waltham, MA, United States); Protein electrophoresis, Electric transfer system, Gel imaging analysis system (Bio-Rad, Hercules, CA, United States); Constant temperature water bath (Shanghai, Baoling Instrument Equipment Co., Ltd.); Carbon dioxide constant temperature incubator, Ice machine (Sanyo, Japan); Ultra-clean workbench, High Pressure Steam Sterilizer (Shandong, BIOBASE); Fluorescence quantitative PCR machine (IT-IS company, United Kingdom); Foot swelling degree measuring instrument (Ugo Basile company, Italy); Small animal live optical imaging system (Shanghai, PerkinElmer Enterprise Management Co., Ltd.); Pipette gun (Eppendorf, Germany); Electric heating constant temperature sink (Shanghai, Huitai Instrument Manufacturing Co., Ltd.).
+ Open protocol
+ Expand
2

Enzymatic Assay of β-D-Glucosidase

Check if the same lab product or an alternative is used in the 5 most similar protocols
β-D-glucosidase was purchased from Shanghai Yuanye Biotechnology Co., Ltd., Shanghai, China; methanol (chromatographic pure), ethyl acetate (chromatographic pure), citric acid, disodium hydrogen phosphate, and anhydrous sodium carbonate were obtained from Tianjin Damao Chemical Reagent Factory, Tianjin, China; concentrator plus vacuum concentrator, ultra-low temperature refrigerator, electronic balance, ultrasonic cleaner, pipette gun were obtained from Eppendorf, Hamburg, Germany; thermostatic bath was obtained from PolyScience, Niles, IL, USA; acid meter, Trace1300 gas chromatograph, Trace ISQ mass spectrometer (GC-MS), and NanoDrop 2000 nucleic acid analyzer were obtained from Thermo, Waltham, MA, USA; high-efficiency plant total RNA extraction kit, UnionScript First-strand cDNA synthesis mix for qPCR kit, and real-time fluorescence quantitative SYBR GreenⅠMaster kit were purchased from Beijing Jinsha Biological Co., Ltd., Beijing, China; LightCycler 480 quantitative PCR instrument was obtained from Roche, Basel, Switzerland.
+ Open protocol
+ Expand
3

Comprehensive Research Apparatus Setup

Check if the same lab product or an alternative is used in the 5 most similar protocols
The apparatus used in this study included a biosafety cabinet (Suzhou Airtech, Suzhou, China), CO2 incubator, centrifuge, and vortex mixer (Thermo, China), cell counter (ADAM™), inverted microscope (Motic), 4°C medical refrigerator and −20°C refrigerator (Panasonic Appliances Cold Chain [Dalian], Dalian, China), −80°C ultra-low temperature refrigerator and electric pipette (Thermo, China), pipette gun (Eppendorf, Shanghai, China), and super thermostatic water bath (Shanghai Boxun Medical Equipment Factory, Shanghai, China).
+ Open protocol
+ Expand
4

Endangered Chinese Alligator Serum Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
As the Chinese alligator is an endangered species, in order to preserve the finite amount of serum, the experiment was designed as follows. Briefly, we took 96-well culture plates, zoned, and marked each plate. For each plate, 100 μL MHB was pipetted to wells 2–11 via a pipette gun (Eppendorf, Hamburg, Germany), and 200 μL MHB was pipetted into well 12. Then 200 μL P/S or serum was pipetted into well 1, and 100 μL of the respective treatment was pipetted to well 2. The liquid was mixed adequately with a pipette gun to suck it up and blow it back, and this step was repeated 3–5 times. Then 100 μL was removed from well 2 to and pipetted into well 3, this operation was repeated, until reaching well 10. The 100 μL solution in well 10 was not mixed in this manner and remained unchanged. Then, we pipetted 100 μL of the bacteria solution into wells 1–11 (Figure S5). Following culturing at 37 °C for 18 h, spectrophotometry of the solution was conducted with SynergyMx M5 Full-band Multifunctional Microplate reader (Molecular Devices, San Jose, CA, USA). This experiment was repeated three times.
+ Open protocol
+ Expand
5

Evaluation of rt-PA and u-PA in Dissolving Blood Clots

Check if the same lab product or an alternative is used in the 5 most similar protocols
A total of 40 ml of arterial blood was drawn from each patient and randomly injected into 10 blood collection tubes (4 ml/tube), centrifuged, then the serum was aspirated to prepare the blood clot model, and divided into the standard group, control group, 0.125 mg/3ml, 0.25 mg/3ml, 0.5 mg/3ml, 1 mg/3ml, 2 mg/3ml, 3 mg/3ml rt-PA groups, 20,000 U, and 40,000 U urokinase (u-PA) groups. No intervention in the standard group for checking blood clot volume, the control group was added with 3 ml saline, then 0.125 mg/3 ml, 0.25 mg/3 ml, 0.5 mg/3 ml, 1 mg/3 ml, 2 mg/3 ml, 3 mg/3 ml rt-PA groups were added with the corresponding dose of the rt-PA (Boehringer-Ingelheim, Germany), and the 20,000 and 40,000 U u-PA groups were added with the corresponding dose of the u-PA (NDPHARM, China). Then, the tube was placed in a 37°C electric-heated thermostatic water bath (Wuxi Yierda, China), and the corresponding dissolved volume or blood clot volume was measured 30, 60, 90, 120, and 150 min after the intervention with a pipette gun (Eppendorf, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!