PTX-3 measurements were performed with the Quantikine® Human Pentraxin 3/TSG-14 Immunoassay (R&D Systems Inc., Minneapolis, USA) using plasma from EDTA monovettes®. IL-6 and PCT were measured in serum. IL-6 was measured with reagents from Roche Diagnostics (Roche Diagnostics, Mannheim, Germany) and PCT was measured with reagents from Thermo Fisher Scientific (Thermo Fisher Scientific Clinical Diagnostics, BRAHMS GmbH, Henningsdorf, Germany). The assays were performed on a Cobas e601 twin module and on a Cobas e602 module (Roche Diagnostics, Mannheim, Germany). Interleukin-6 and PCT measurements were performed at the central laboratory in Nuremberg, Germany.
Cobas e601 twin module
The Cobas e601 twin module is a laboratory instrument designed for the analysis of immunoassay samples. It features two analysis modules operating in parallel to increase sample throughput. The Cobas e601 twin module is capable of performing a variety of immunoassay tests, but a detailed description of its intended use or interpretation of its capabilities is not provided.
2 protocols using cobas e601 twin module
Biomarker Measurement in Blood Samples
PTX-3 measurements were performed with the Quantikine® Human Pentraxin 3/TSG-14 Immunoassay (R&D Systems Inc., Minneapolis, USA) using plasma from EDTA monovettes®. IL-6 and PCT were measured in serum. IL-6 was measured with reagents from Roche Diagnostics (Roche Diagnostics, Mannheim, Germany) and PCT was measured with reagents from Thermo Fisher Scientific (Thermo Fisher Scientific Clinical Diagnostics, BRAHMS GmbH, Henningsdorf, Germany). The assays were performed on a Cobas e601 twin module and on a Cobas e602 module (Roche Diagnostics, Mannheim, Germany). Interleukin-6 and PCT measurements were performed at the central laboratory in Nuremberg, Germany.
Measurement of Presepsin, IL-6, and PCT
Presepsin measurements were performed with the PATHFAST® immunoassay analytical system (PROGEN Biotechnik GmbH, Germany; Mitsubishi Chemical Medience Corporation, Japan) using plasma from EDTA monovettes® [8 (link),19 (link)]. IL-6 and PCT were measured in serum. IL-6 was measured with reagents from Roche Diagnostics (Roche Diagnostics, Mannheim, Germany) and PCT was measured with reagents from Thermo Fisher Scientific (Thermo Fisher Scientific Clinical Diagnostics, BRAHMS GmbH, Henningsdorf, Germany). The assays were performed on a Cobas e601 twin module (Roche Diagnostics, Mannheim, Germany). IL-6 and PCT measurements were performed at the central laboratory in Nuremberg, Germany.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!