Linear polystyrene calibration standards

Manufactured by Merck Group
Sourced in United States

Linear polystyrene calibration standards are laboratory tools used to calibrate and validate the performance of analytical instruments, such as size exclusion chromatography (SEC) systems. They provide a set of well-characterized polymer samples with known molecular weights, which are used to establish the relationship between elution volume and molecular weight for SEC analysis.

Automatically generated - may contain errors

2 protocols using linear polystyrene calibration standards

1

Gel Permeation Chromatography of Polymer Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The film samples for each timepoint were frozen at −20 °C and lyophilised. Each sample was then dissolved in THF at a concentration of 2 mg mL−1 and filtered through a cotton filter prior to passing into a HPLC vial in order to remove the insoluble salts from the aqueous media used to carry out the reaction. Gel permeation chromatography was carried out at 30 °C on an Agilent Technologies HPLC System (1260 series, Agilent Technologies, Palo Alto, CA, USA) connected to a 6.0 mm ID  ×  40 mm L HHR-H, 5 μm Guard column and a 7.8 mm ID  ×  300 mm L GMHHR-N, 5 μm TSK gel liquid chromatography column (Tosoh Bioscience, Tessenderlo, Belgium) using 1 mL min−1 THF as the mobile phase. An Agilent Technologies G1362A refractive index detector was employed for detection. The molecular weights of the polymers were calculated using linear polystyrene calibration standards in the 400–2,000,000 Da Mp range (Sigma-Aldrich, St. Louis, MO, USA). Data processing was carried out using the Agilent GPC/SEC software (Version 1.2, Figures S7–S10).
+ Open protocol
+ Expand
2

Gel Permeation Chromatography of Polymer Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The samples were dissolved in CHCl3 at a concentration of 2 mg mL−1 and filtered through cotton filters. Gel permeation chromatography was carried out at 30 °C on an Agilent Technologies HPLC System (Agilent Technologies 1260 Infinity) connected to a 17,369 6.0 mm ID × 40 mm L HHR-H, 5 μm Guard column and a 18,055 7.8 mm ID × 300 mm L GMHHR-N, 5 μm TSK gel liquid chromatography column (Tosoh Bioscience, Tessenderlo, Belgium) using CHCl3 as an eluent (at a flow rate of 1 mL min−1). An Agilent Technologies G1362A refractive index detector was employed for detection. The molecular weights of the polymers were calculated using linear polystyrene calibration standards (250–70,000 Da) purchased from Sigma-Aldrich.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!