Fitc conjugated cd71 okt9

Manufactured by Thermo Fisher Scientific

FITC-conjugated CD71 (OKT9) is a fluorescently labeled monoclonal antibody that binds to the transferrin receptor (CD71) on the surface of cells. The FITC (Fluorescein Isothiocyanate) fluorescent label allows for the detection and analysis of CD71-expressing cells using flow cytometry or other fluorescence-based techniques.

Automatically generated - may contain errors

4 protocols using fitc conjugated cd71 okt9

1

Erythroid Cell Phenotyping by Flow Cytometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
For flow cytometry analysis, in vitro cultured erythroid cells were washed in FACS buffer (1% FBS in PBS) before antibody staining. The following antibodies at indicated dilutions were used in this study: 1:50 APC-conjugated CD235a (Glycophorin A, clone HIR2, 50–153-69, eBioscience), 1:50 FITC-conjugated CD71 (OKT9, 14–0719-82, eBioscience), 1:50 APC-conjugated CD49d (9F10, Biolegend, 304308) and 1:200 FITC-conjugated BAND3 (An et al., 2014 (link); Hu et al., 2013 (link)). For live/ dead cell discrimination Sytox Blue was used according to the manufacturer’s instructions (Thermo Fisher, S34857). For apoptosis analysis, BV421-Annexin V (BD Bioscience, 563973) was used in combination with Sytox Orange according to the manufacturer’s instructions (Thermo Fisher, S34861). FACS analysis was conducted on a BD Bioscience Fortessa flow cytometer at the Whitehead Institute Flow Cytometry core. Data were analyzed using FlowJo software v10.4.2.
+ Open protocol
+ Expand
2

Multicolor Flow Cytometry of Erythroid Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
For flow cytometry analysis, in vitro cultured erythroid cells were washed in PBS and stained with propidium iodide (PI), 1:60 APC-conjugated Glycophorin A/CD235a (HIR2, 17-9987-42, eBioscience), 1:60 FITC-conjugated CD71 (OKT9, 11-0719-42, eBioscience), 1:60 PE-conjugated CD41a (HIP8, 12-0419-42, eBioscience) and 1:60 PE-conjugated CD11b (ICRF44, 12-0118-42, eBioscience). For apoptosis analysis the Annexin V-APC staining kit was used according to the manufacturer’s instructions (550474, BD Pharmingen). FACS analysis was conducted on a BD Bioscience LSR II flow cytometer. Data were analyzed using FlowJo 8.6.9 (TreeStar).
+ Open protocol
+ Expand
3

Erythroid Cell Phenotyping by Flow Cytometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
For flow cytometry analysis, in vitro cultured erythroid cells were washed in FACS buffer (1% FBS in PBS) before antibody staining. The following antibodies at indicated dilutions were used in this study: 1:50 APC-conjugated CD235a (Glycophorin A, clone HIR2, 50–153-69, eBioscience), 1:50 FITC-conjugated CD71 (OKT9, 14–0719-82, eBioscience), 1:50 APC-conjugated CD49d (9F10, Biolegend, 304308) and 1:200 FITC-conjugated BAND3 (An et al., 2014 (link); Hu et al., 2013 (link)). For live/ dead cell discrimination Sytox Blue was used according to the manufacturer’s instructions (Thermo Fisher, S34857). For apoptosis analysis, BV421-Annexin V (BD Bioscience, 563973) was used in combination with Sytox Orange according to the manufacturer’s instructions (Thermo Fisher, S34861). FACS analysis was conducted on a BD Bioscience Fortessa flow cytometer at the Whitehead Institute Flow Cytometry core. Data were analyzed using FlowJo software v10.4.2.
+ Open protocol
+ Expand
4

Multicolor Flow Cytometry of Erythroid Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
For flow cytometry analysis, in vitro cultured erythroid cells were washed in PBS and stained with propidium iodide (PI), 1:60 APC-conjugated Glycophorin A/CD235a (HIR2, 17-9987-42, eBioscience), 1:60 FITC-conjugated CD71 (OKT9, 11-0719-42, eBioscience), 1:60 PE-conjugated CD41a (HIP8, 12-0419-42, eBioscience) and 1:60 PE-conjugated CD11b (ICRF44, 12-0118-42, eBioscience). For apoptosis analysis the Annexin V-APC staining kit was used according to the manufacturer’s instructions (550474, BD Pharmingen). FACS analysis was conducted on a BD Bioscience LSR II flow cytometer. Data were analyzed using FlowJo 8.6.9 (TreeStar).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!