The largest database of trusted experimental protocols

Gemini diffractometerabsorption

Manufactured by Agilent Technologies

The Gemini diffractometer is a lab equipment product designed for X-ray diffraction analysis. It is capable of measuring the absorption of X-rays by a sample, which can provide information about the material's structure and composition. The core function of the Gemini diffractometer is to perform X-ray diffraction experiments and measure the absorption of X-rays by the sample.

Automatically generated - may contain errors

4 protocols using gemini diffractometerabsorption

1

Single Crystal X-ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Agilent Xcalibur, Eos, Gemini diffractometer

Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2014 ▸ ) Tmin = 0.834, Tmax = 1.000

14345 measured reflections

6319 independent reflections

4721 reflections with I > 2σ(I)

Rint = 0.032

+ Open protocol
+ Expand
2

Single-crystal X-ray Structural Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Agilent Xcalibur, Eos, Gemini diffractometer

Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2014 ▸ ) Tmin = 0.715, Tmax = 0.967

16365 measured reflections

8908 independent reflections

6481 reflections with I > 2σ(I)

Rint = 0.036

+ Open protocol
+ Expand
3

Single Crystal X-ray Diffraction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Agilent Xcalibur, Eos, Gemini diffractometer

Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2014 ▸ ) Tmin = 0.828, Tmax = 1.000

3844 measured reflections

2189 independent reflections

1944 reflections with I > 2σ(I)

Rint = 0.025

+ Open protocol
+ Expand
4

Single Crystal X-ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Agilent Xcalibur, Eos, Gemini diffractometer

Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▶ ) Tmin = 0.516, Tmax = 0.750

11078 measured reflections

5728 independent reflections

5570 reflections with I > 2σ(I)

Rint = 0.021

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!