The largest database of trusted experimental protocols

Jnm eca500 nmr spectrometer

Manufactured by JEOL
Sourced in Japan

The JNM-ECA500 NMR spectrometer is a high-performance nuclear magnetic resonance (NMR) instrument developed by JEOL. It is designed to analyze the structural and chemical properties of materials by detecting and measuring the resonance frequencies of atomic nuclei within a sample. The JNM-ECA500 operates at a magnetic field strength of 500 MHz, providing high-resolution data for various applications.

Automatically generated - may contain errors

5 protocols using jnm eca500 nmr spectrometer

1

Comprehensive Characterization of Gel Materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 1H NMR spectra were recorded at 500 MHz with a JEOL JNM-ECA 500 NMR spectrometer. The FGMAS NMR spectra were recorded at 400 MHz with a JEOL JNM-ECA 400 NMR spectrometer. The sample spinning rate was 8 kHz. In all NMR measurements, chemical shifts were referenced to the solvent values (δ = 2.49 ppm and 4.79 ppm for DMSO-d6 and D2O, respectively). The contact angles were measured by a Dynamic Contact Angle Analyzer (DCA-700, Kyowa Interface Science Ltd.). The IR spectra of the gels were measured using a JASCO FT/IR-410 spectrometer with a KBr disc, while those of the substrates were measured using a JASCO FT/IR-6000 spectrometer via the attenuated total reflection method (ATR). The mechanical properties of the gels were measured by a mechanical tension testing system (Rheoner, RE-33005, Yamaden Ltd.), while the dynamic viscoelasticity was measured using an Anton Paar MCR301 rheometer. X-ray photoelectron spectroscopy (XPS) data were collected with an AXIS 165 (KRATOS ANALYTICAL) using a monochromatic Al-Kα X-ray source.
+ Open protocol
+ Expand
2

Extraction and Characterization of Polyhydroxyalkanoates

Check if the same lab product or an alternative is used in the 5 most similar protocols
Extraction and estimation of PHA was performed following the procedures reported (Law and lepecky, 1960 ; Venkata Mohan and Venkateswar Reddy, 2013; Venkateswar Reddy et al. 2016 ). 1 H (500 MHz) NMR spectra was recorded on a JNM-ECA500 NMR spectrometer (JEOL, Japan) at 20 °C to know the structure of polymer. Samples of produced PHA and standard P3HB/ P(3HB-co-3HV) (Aldrich) were prepared by dissolving in deuterated chloroform (CDCl3), and then were filtrated with cotton. The signals of tetramethylsilane (TMS) and CDCl3 were used as the standards for chemical shift of 1 H spectra.
Number and weight average molecular mass (Mn and Mw) of standard and sample P3HB/ P(3HB-co-3HV) were measured using GPC 900-1 (JASCO, Japan) equipped with two Shodex K-806L columns and an RI detector. Chloroform was used as an eluent at 40 ºC and polystyrene standards (Mn = 1,680-3,065,000) were employed for calibration.
+ Open protocol
+ Expand
3

Deacetylation and NMR Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The polysaccharide was de-O-acetylated completely using 0.1 M NaOH at 37℃ for 4 h, following the procedure reported by Bhattacharjee et al. 10) . 1 H NMR spectra were recorded with a JNM-ECA500 NMR spectrometer(JEOL, Tokyo, Japan) using solutions in D2 O at 90℃. Sodium 3-(trimethylsilyl) -1-propanesulfonate was used as the external standard.
+ Open protocol
+ Expand
4

NMR Spectral Analysis of PHA

Check if the same lab product or an alternative is used in the 5 most similar protocols
1 H (500 MHz) NMR spectra was recorded on a JNM-ECA500 NMR spectrometer (JEOL, Japan) at 20 °C. Samples of produced PHA and standard P3HB/ P(3HB-co-3HV) (Aldrich) were prepared by dissolving in deuterated chloroform (CDCl3), and then were filtrated with cotton. The signals of tetramethylsilane (TMS) and CDCl3 were used as the standards for chemical shift of 1 H spectra.
+ Open protocol
+ Expand
5

NMR Characterization of Produced PHB

Check if the same lab product or an alternative is used in the 5 most similar protocols
1 H (500 MHz) and 13 C (125 MHz) NMR spectra were recorded on a JNM-ECA500 NMR spectrometer (JEOL, Japan) at 20°C. Samples of produced PHB and standard PHB (Aldrich) were prepared by dissolving in deuterated chloroform (CDCl3), and then were filtrated with cotton. The signals of tetramethylsilane (TMS) and CDCl3 were used as the standards for chemical shift of 1 H and 13 C spectra, respectively.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!