The largest database of trusted experimental protocols

Cobas ampliprep v2.0 taqman 48 system

Manufactured by Roche

The COBAS Ampliprep V2.0/Taqman-48 system is an automated molecular diagnostic instrument designed for nucleic acid extraction and real-time PCR amplification and detection. The system is capable of processing multiple sample types and is intended for in vitro diagnostic use.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using cobas ampliprep v2.0 taqman 48 system

1

HIV-1 Infection in Humanized Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sixteen humanized mice (Hu-mice, 4 males and 12 females) were infected intraperitoneally (IP) with 2 × 104 tissue culture infectious dose 50 (TCID50) of HIV-1ADA at 20 weeks age35 (link)–39 (link),46 (link). Eight Hu- NSG mice served as uninfected aged-matched controls. Peripheral blood samples were collected every four weeks via submandibular vein bleeding to assess HIV-1 viral RNA. Plasma HIV-1 RNA levels were measured using an automated COBAS Ampliprep V2.0/Taqman-48 system (Roche Molecular Diagnostics, Basel, Switzerland) as per the manufacturer’s instructions. The detection limit after dilution factor adjustment was 400 viral RNA copies/ml.
+ Open protocol
+ Expand
2

Humanized Mouse Model of HIV Infection

Check if the same lab product or an alternative is used in the 5 most similar protocols
Twenty weeks after humanization, 12 Hu-mice were infected intraperitoneally (IP) with 2 × 104 tissue culture infectious dose 50 (TCID50) of HIV-1ADA (a macrophage tropic viral strain) (61 (link)–63 (link)). An additional six Hu-mice served as uninfected aged-matched controls. Peripheral blood samples were collected every four weeks via submandibular vein bleeding to assess HIV-1 viral RNA and to assess the dynamics of human immune cell markers by flow cytometric analysis. Plasma HIV-1 RNA levels were measured using an automated COBAS Ampliprep V2.0/Taqman-48 system (Roche Molecular Diagnostics, Basel, Switzerland) as per the manufacturer's instructions. The detection limit after dilution factor adjustment was 200 viral RNA copies/mL.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!