The largest database of trusted experimental protocols

1260 lc instrument

Manufactured by Agilent Technologies
Sourced in United States

The 1260 LC instrument is a liquid chromatography system designed for analytical applications. It is capable of performing high-performance liquid chromatography (HPLC) and ultra-high-performance liquid chromatography (UHPLC) separations. The instrument includes a solvent delivery system, an autosampler, a column compartment, and a detector for data acquisition.

Automatically generated - may contain errors

2 protocols using 1260 lc instrument

1

Glycopeptide Fractionation by HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
The dried IGPs were resuspended in 2% ACN/20 mM NH4COOH and fractionated through high pH reverse-phase high-performance liquid chromatography with Agilent RP Zorbax 300 Å Extend C18 column (250 mm × 4.6 mm, OD 5 μm) in an Agilent 1260 LC instrument. Intact glycopeptides were first separated into 96 fractions through a gradient of mobile phases A (2% ACN/5 mM NH4COOH, pH 10) and B (90% ACN/5 mM NH4COOH, pH 10) at a flow rate of 0.2 ml/min. A total of 120 min was used for gradient elution, 0 to 2% B for 7 min, 2 to 8% B for 35 min, 8 to 16% B for 35 min, 16 to 35% B for 10 min, 35 to 95% B for 5 min, 95 to 95% B for 28 min. Then, IGPs were integrated into 12 fractions and dried by vacuum centrifuging.
+ Open protocol
+ Expand
2

Polysaccharide Characterization via HPGPC

Check if the same lab product or an alternative is used in the 5 most similar protocols
The homogeneity and molecular weight distribution of polysaccharide fractions were determined by HPGPC on an Agilent 1260 LC instrument equipped with a refractive index detector (RID), a variable wavelength detector (VWD), coupled with an Ultrahydrogel TM 1000 column (7.8 mm × 300 mm, Waters, USA) and an Ultrahydrogel TM Linear column (7.8 mm × 300 mm, Waters, USA).
Polysaccharide solution was filtered through 0.45 μm filter prior to injection, with 0.1 M NaCl/0.02% NaN3 aqueous solution as mobile phase at a flow rate of 0.6 mL/min. The molecular weight of polysaccharides was estimated using a standard curve prepared by T-series dextrans.
According to the information obtained from HPGPC that would be discussed later in this study, we selected NCSP-50 for the following analysis.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!