Aria mx3000

Manufactured by Agilent Technologies

The Aria Mx3000 is a qPCR (quantitative Polymerase Chain Reaction) instrument manufactured by Agilent Technologies. It is designed to perform real-time PCR experiments for gene expression analysis, genotyping, and other applications that require precise quantification of nucleic acids.

Automatically generated - may contain errors

3 protocols using aria mx3000

1

Comprehensive RNA Extraction and qPCR Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total RNA was isolated using Qiagen RNeasy plus mini kit. cDNA was synthesized with a High-Capacity Reverse Transcription kit (Thermo Fischer). qPCR was performed using Brilliant III SYBR Master Mix using Aria Mx3000 or AriaMx real time PCR machines (Agilent Genomics). Raw Ct values were normalized to geometric mean of ACTB and B2M transcripts before normalization to experimental control indicated. RT-qPCR primers are listed in Supplemental Table 2.
+ Open protocol
+ Expand
2

Quantitative Real-Time PCR protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Appropriate primers (Table S5) were used in 10 μl reactions with the Maxima 2 × SYBR Green/ROX qPCR Master Mix (Thermo Scientific) and RT‐qPCR was run on Aria Mx3000 (Agilent) with 40 cycles at 60°C for 10 s followed by 72°C for 15 s and a subsequent melting curve (65–95°C). HvUbiquitin was measured as a housekeeping gene (Schnepf et al., 2018 (link)) and foldchanges were calculated via the 2−∆∆Ct method by Livak and Schmittgen (2001 (link)).
+ Open protocol
+ Expand
3

Comprehensive RNA Extraction and qPCR Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total RNA was isolated using Qiagen RNeasy plus mini kit. cDNA was synthesized with a High-Capacity Reverse Transcription kit (Thermo Fischer). qPCR was performed using Brilliant III SYBR Master Mix using Aria Mx3000 or AriaMx real time PCR machines (Agilent Genomics). Raw Ct values were normalized to geometric mean of ACTB and B2M transcripts before normalization to experimental control indicated. RT-qPCR primers are listed in Supplemental Table 2.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.