The largest database of trusted experimental protocols

Magnetom trio tim syngo 3 tesla system

Manufactured by Siemens

The Magnetom Trio Tim Syngo 3 Tesla system is a magnetic resonance imaging (MRI) system produced by Siemens. It operates at a field strength of 3 Tesla, which is a measure of the strength of the magnetic field used to generate images. The system utilizes the Syngo software platform developed by Siemens for image acquisition and processing.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using magnetom trio tim syngo 3 tesla system

1

Harmonized MRI Protocol for Multicenter Cognitive Studies

Check if the same lab product or an alternative is used in the 5 most similar protocols
The MRI protocol had been harmonized amongst the different PharmaCog project centers36 (link). Images were acquired using a Siemens Magnetom Trio Tim Syngo 3 Tesla system at the MRI Core Facility (IDIBAPS) of the Hospital Clinic of Barcelona, Barcelona, and with a Siemens Magnetom Verio 3 T at the Hôpital Timone in Marseille. All participants underwent fMRI acquisitions during the recognition memory task. Further, T1-weighted structural images were used for neuronavigation purposes (MRI parameters are detailed on SM).
+ Open protocol
+ Expand
2

Multimodal Neuroimaging Protocol for Resting-State fMRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
All participants were scanned with a Siemens Magnetom Trio Tim Syngo 3 Tesla system at the MRI Core Facility (IDIBAPS) of the Hospital Clinic of Barcelona, Barcelona, Spain. In the succeeding, only the acquisitions used in this investigation, both for research purposes and clinical screening, are detailed. Three identical rs-fMRI datasets [T2*-weighted GE-EPI sequence; interleaved acquisition; repetition time (TR) = 2,700 ms; echo time (TE) = 30 ms; 40 slices per volume; slice thickness = 3.0 mm; interslice gap = 15%; voxel size = 3.0 x 3.0 x 3.0 mm; field of view (FOV) = 216 mm; 178 volumes] were acquired, one each experimental day. Furthermore, a hr-3D structural dataset [T1-weighted magnetization-prepared rapid gradient-echo (T1-weighted MPRAGE); sagittal plane acquisition; TR = 2,300 ms; TE = 2.98 ms, inversion time (IT) = 900 ms; slice thickness = 1.0 mm; voxel size = 1.0 x 1.0 x 1.0 mm; FOV = 256 mm; 240 slices] was acquired on experimental day 1. In addition, an axial FLAIR sequence (TR = 9,000 ms; TE = 96 ms; slice thickness = 3.0 mm; FOV = 240 mm; 40 slices) was obtained on experimental day 2 (see Figure 1).
+ Open protocol
+ Expand
3

Multimodal Brain Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All participants were scanned with a Siemens Magnetom Trio Tim Syngo 3 Tesla system at the Unitat d’Imatge per Ressonància Magnètica IDIBAPS (Institut d’Investigacions Biomèdiques August Pi i Sunyer) at Hospital Clínic i Provincial de Barcelona, Barcelona, Spain. The imaging sequences were acquired with the following parameters.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!