Orion 230a ph meter

Manufactured by Thermo Fisher Scientific
Sourced in Switzerland, United States

The Orion 230A pH meter is a laboratory instrument designed to measure the pH of a solution. It provides accurate and reliable pH measurements, allowing users to monitor and analyze the acidity or alkalinity of various samples.

Automatically generated - may contain errors

4 protocols using orion 230a ph meter

1

Proximate Meat Composition and pH Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
The proximate composition of meat was measured according to the AOAC methods (1998) . Meat pH was measured as follows: 10 g of meat was homogenized with distilled water (90 mL) for 15 s using a homogenizer (Polytron PT-2500E; Kinematica, Lucerne, Switzerland), according to Kim et al. (2019a) (link), and the pH of the homogenate was determined using an Orion 230A pH meter (Thermo Fisher Scientific, Waltham, MA).
+ Open protocol
+ Expand
2

Breast Meat Quality Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
For breast meat (Pectoralis major), quality, pH, cooking loss, water holding capacity (WHC), and shear force were analyzed following the methods described in [16 (link)]. The pH of the right breast meat was measured using an Orion 230A pH meter (Thermo Fisher Scientific, Waltham, MA, USA) as follows: 10 g of meat was homogenized with distilled water (90 mL) using a homogenizer (Polytron PT-2500E; Kinematica, Lucerne, Switzerland) for 15 s, and the shear force of the breast meat was measured using a texture analyzer TA1 (Lloyd Instruments, Fareham, UK) with a V blade. To measure cooking loss, the samples were weighed, placed in a plastic bag, and then cooked in a water bath (80 °C) for 20 min. After cooking, the samples were cooled at room temperature for 10 min, and cooking loss was calculated as the percentage of loss in relation to the initial weight. The left breast meat was used to measure water holding capacity (WHC). Breast meat (0.5 g) was placed on a Millipore Ultrafree-MC (Millipore, Bedford, MA, USA), boiled at 80 °C for 20 min, cooled to room temperature, and then centrifuged at 4 °C for 10 min at 2000× g using a centrifuge machine to measure water loss.
+ Open protocol
+ Expand
3

Measuring Dairy Beef Round pH and Color

Check if the same lab product or an alternative is used in the 5 most similar protocols
To determine the pH of dairy beef round, 3 g sample was homogenized with 27 mL
distilled water for 15 s through a homogenizer (Polytron PT-2500E; Kinematica,
Lucerne, Switzerland) and then, pH was evaluated by Orion 230A pH meter (Thermo
Fisher Scientific, Waltham, MA, USA), which was calibrated using pH 4.1 and 7.0
buffer before use.
Meat color of dairy beef round was measured by Chroma Meter CR-400 instrument
(Minolta, Osaka, Japan) using CIE L*, CIE a*, and CIE b* after calibration the
Chroma Meter using white plate references (Y: 93.60, x: 0.3134, y: 0.3194).
Cooking loss was obtained percentage of the difference between before and after
cooking weights (Gajaweera et al.,
2020
).
+ Open protocol
+ Expand
4

Meat Sample pH Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
After blending 10 g of meat sample with 90 mL of distilled water for 15 s
using a homogenizer (Polytron R PT-2500E, Kinematica, Lucerne, Switzerland),
the pH values of the homogenates were determined using an Orion 230A pH
meter (Thermo Fisher Scientific, Waltham, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!