PE-CF594-CD183 is a fluorochrome-conjugated antibody used in flow cytometry applications to detect the expression of the CD183 protein. It is a tool for researchers to identify and quantify cells expressing the CD183 marker.

Automatically generated - may contain errors

2 protocols using pe cf594 cd183

1

Comprehensive Immunophenotyping of Whole Blood

Check if the same lab product or an alternative is used in the 5 most similar protocols
Whole blood (150μl) was immunolabeled for 15 minutes at room temperature using the following antibodies [with catalog numbers; concentration]: 5μl for each of the following APC-Cy7-CD4 [557871; 0.2mg/ml], PerCP-Cy5.5-CD8 [560662; 0.05mg/ml], Alexa Fluor 700-CD14 [557923; 0.2mg/ml], BV605-CD25 [562660; 0.025mg/ml], PE-Cy7-CD196 [560620; 0.2mg/ml], BV421-CD194 [562579; 0.2mg/ml], PE-CF594-CD183 [562451; 0.2mg/ml], PE-CD127 [557938; 0.2mg/ml], V500-CD19 [561121; 0.2mg/ml] and 20μl of the following: FITC-CD3 [555339; 0.05mg/ml], and APC-CD56 [555518; 0.025mg/ml] (all from BD Biosciences) and 35μl buffer solution (BD Canada). After the immunolabelling was completed, red blood cells were lysed (0.06M NH4Cl, 4mM KHCO3, 0.052mM EDTA), and peripheral blood mononuclear cells were washed with PBS, PFA-fixed, and analyzed using a flow cytometer (LSR Fortessa, BD Biosciences). A minimum of 300,000 events were acquired per sample. Data analysis was performed using FlowJo (Tree Star Inc).
+ Open protocol
+ Expand
2

Multiparametric Flow Cytometry Immunophenotyping

Check if the same lab product or an alternative is used in the 5 most similar protocols
Whole blood (100 μl) was immunolabeled for 15 minutes at room temperature using the following antibodies: FITC-CD3, APC-Cy7-CD4, PerCP-Cy5.5-CD8, PE-CD127, V500-CD19, PE-CF594-CD183, PE-Cy7-CD196, BV605-CD25, BV421-CD194, Alexa Fluor 700-CD14, and APC-CD56 (all from BD Biosciences, Mississauga, Canada). Red blood cells were lysed (0.06 M NH 4 Cl, 4 mM KHCO 3 , 0.052 mM EDTA), and peripheral blood mononuclear cells washed with PBS, PFA-fixed, and analyzed using a flow cytometer (LSRFortessa, BD Biosciences, Ontario, Canada). A minimum of 300,000 events were acquired per sample. Data analysis was performed using FlowJo (Tree Star Inc, Ashland, OR) (gating strategy is shown in Supplemental Figure 1).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!