The largest database of trusted experimental protocols

Anti type x collagen col 10 antibody

Manufactured by Merck Group
Sourced in Germany, United States

The Anti-type-X collagen (COL-10) antibody is a laboratory reagent used for the detection and quantification of type-X collagen in biological samples. It is a specific and sensitive tool for researchers studying the role of type-X collagen in various biological processes.

Automatically generated - may contain errors

11 protocols using anti type x collagen col 10 antibody

1

Chondrogenic Differentiation Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were from Sigma (Munich, Germany) unless otherwise indicated. Recombinant TGF-β was from R&D Systems (Wiesbaden, Germany). The anti-SOX9 (C-20) antibody was from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-type-II collagen (II-II6B3) antibody from the NIH Hybridoma Bank (University of Iowa, Ames, USA), and the anti-type-X collagen (COL-10) antibody from Sigma. Biotinylated secondary antibodies and ABC were from Vector Laboratories (Grünberg, Germany). Luciferase activity was determined with the Luciferase Assay System (Promega GmbH, Mannheim, Germany) and normalized to total cellular proteins using the BCA protein assay kit (Pierce Thermo Scientific, Fisher Scientific GmbH, Schwerte, Germany). The Cell Proliferation Reagent WST-1 was from Roche Applied Science (Mannheim, Germany). The type-II collagen contents were measured with the native type-II collagen Arthrogen-CIA Capture ELISA kit (Chondrex, Redmond, WA, USA) and those for type-X collagen using a COL-10 ELISA (Antibodies-Online, Aachen, Germany).
+ Open protocol
+ Expand
2

Chondrogenic Differentiation Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were from Sigma (Munich, Germany) unless otherwise indicated. Recombinant TGF-β3 was from R&D Systems (Wiesbaden, Germany). The anti-SOX9 (C-20) antibody was from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-type-II collagen (II-II6B3) antibody from the NIH Hybridoma Bank (University of Iowa, Ames, USA), and the anti-type-X collagen (COL-10) antibody from Sigma. Biotinylated secondary antibodies and the ABC kit were from Vector Laboratories (Grünberg, Germany). The β-gal Staining Kit and the Cell Proliferation Reagent WST-1 were from Roche Applied Science (Mannheim, Germany). The Beta-Glo® Assay System was from Promega (Mannheim, Germany). The type-II collagen ELISA (Human COL2A1) was purchased at Cusabio (College Park, MD, USA).
+ Open protocol
+ Expand
3

Chondrocyte Differentiation Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were from Sigma (Munich, Germany) unless otherwise indicated. Recombinant FGF-2 and TGF-β3 were purchased at Peprotech (Hamburg, Germany). The dimethylmethylene blue dye was from Serva (Heidelberg, Germany). The anti-TGF-β (V) and anti-SOX9 (C-20) antibodies were from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-type II collagen (II-II6B3) antibody from the NIH Hybridoma Bank (University of Iowa, Ames, IA, USA), the anti-type I collagen (AF-5610) antibody from Acris Antibodies (Hiddenhausen, Germany), and the anti-type X collagen (COL-10) antibody from Sigma. Biotinylated secondary antibodies and the ABC reagent were purchased at Vector Laboratories (Alexis Deutschland GmbH, Grünberg, Germany). The TGF-β enzyme-linked immunosorbent assay (hTGF-β1 Quantikine ELISA) was from R&D Systems (Wiesbaden, Germany).
+ Open protocol
+ Expand
4

Chondrocyte Differentiation Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were purchased at Sigma (Munich, Germany) unless otherwise indicated. The anti-SOX9 (C-20) and anti-TGF-β (V) antibodies were from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-type-II collagen (II-II6B3) from the NIH Hybridome Bank (University of Iowa, Ames, IA, USA), the anti-type-I collagen (AF-5610) antibody from Acris (Hiddenhausen, Germany), and the anti-type-X collagen (COL-10) antibody from Sigma. The biotinylated secondary antibodies and ABC reagent were from Vector Laboratories (Alexis Deutschland GmbH, Grünberg, Germany). The AAVanced Concentration Reagent was from System Bioscience (Heidelberg, Germany) and the Cy3 Ab Labeling Kit from Amersham/GE Healthcare (Munich, Germany). The AAV titration ELISA was from Progen (Heidelberg, Germany). The β-gal staining kit and the Cell Proliferation Reagent WST-1 were purchased at Roche Applied Science (Mannheim, Germany), the Beta-Glo® Assay System at Promega (Mannheim, Germany), and the TGF-β Quantikine ELISA at R&D Systems (Wiesbaden, Germany).
+ Open protocol
+ Expand
5

Pluronic F68 and Tetronic 908 for Chondrocyte Culture

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pluronic® F68 and Tetronic® 908 were kindly provided by BASF (Ludwigshafen, Germany). The anti-TGF-β (V) was from Santa Cruz Biotechnology (Heidelberg, Germany). The anti-type-II collagen (II-II6B3) antibody was from DSHB (Iowa City, IA, USA) and the anti-type-X collagen (COL-10) antibody from Sigma (Munich, Germany). Biotinylated secondary antibodies and the ABC reagent were from Vector Laboratories (Alexis Deutschland GmbH, Grünberg, Germany). The Cy3 Ab Labeling Kit was from Amersham/GE Healthcare (Munich, Germany). The cell proliferation reagent WST-1 and the Cytotoxicity Detection KitPLUS (LDH) were from Roche Applied Science (Mannheim, Germany). The TGF-β enzyme-linked immunosorbent assay (ELISA) (hTGF-β Quantikine ELISA) was from R&D Systems (Wiesbaden, Germany). Other reagents were from Sigma (Munich, Germany).
+ Open protocol
+ Expand
6

Chondrogenic Differentiation Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were purchased at Sigma (Munich, Germany) unless otherwise indicated. 4-Styrenesulfonic acid sodium salt hydrate (NaSS) was from Sigma-Aldrich (cat. no. 434574). The anti-SOX9 (C-20) antibody was from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-type-II collagen (AF-5710) and anti-type-I collagen (AF-5610) antibodies from Acris (Hiddenhausen, Germany), and the anti-type-X collagen (COL-10) antibody from Sigma. The biotinylated secondary antibodies and ABC reagent were from Vector Laboratories (Alexis Deutschland GmbH, Grünberg, Germany). The AAVanced Concentration Reagent was from System Bioscience (Heidelberg, Germany) and the Cell Proliferation Reagent WST-1 from Roche Applied Science (Mannheim, Germany).
+ Open protocol
+ Expand
7

Comprehensive Protein Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were from Sigma, Munich (Germany) unless otherwise indicated. The dimethylmethylene blue dye (DMMB) was from Serva (Heidelberg, Germany). The anti- TGF-β (V) antibody was from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-IGF-I (AF-291-NA) from R&D Systems (Wiesbaden, Germany), the anti-type-II collagen (II-II6B3) antibody from NIH Hybridome Bank (University of Iowa, Ames, IA, USA), the anti-type-I collagen (AF-5610) antibody from Acris Antibodies (Hiddenhausen, Germany), and the anti-type-X collagen (COL10) antibody from Sigma. Biotinylated sondary antibodies and ABC reagent were from Vector Laboratories (Alexis Deutschland, Grünberg, Germany). The TGF-β and IGF-I Quantikine ELISAs were from R&D Systems. The AAVanced Concentration Reagent was from System Bioscience (Heidelberg, Germany).
+ Open protocol
+ Expand
8

Chondrogenic Differentiation Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were from Sigma (Munich, Germany), unless otherwise identified. Recombinant TGF-β (rTGF-β) was purchased at Peprotech (Hamburg, Germany) and the dimethylmethylene blue dye at Serva (Heidelberg, Germany). The anti-FGF-2 (C-18) and anti-SOX9 (C-20) antibodies were from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-type-II collagen (II-II6B3) antibody from the NIH Hybridoma Bank (University of Iowa, Ames, USA), the anti-type-I collagen (AF-5610) antibody from Acris (Hiddenhausen, Germany), and the anti-type-X collagen (COL-10) antibody from Sigma. Biotinylated secondary antibodies and the ABC reagent were obtained from Vector Laboratories (Alexis Deutschland GmbH, Grünberg, Germany). The FGF-2 Quantikine ELISA (DFB50) was from R&D Systems (Wiesbaden, Germany) and the type-II, −I, and -X collagen ELISAs from Antibodies-Online (Aachen, Germany).
+ Open protocol
+ Expand
9

Extracellular Matrix Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Recombinant TGF‐β (rTGF‐β) was purchased at Peprotech (Hamburg, Germany), dimethylmethyleneblue (DMMB) at Serva (Heidelberg, Germany) and diaminobenzidine (DAB) at Sigma‐Aldrich (Munich, Germany). The anti‐IGF‐I (AF‐291‐NA) antibody was from R&D Systems (Wiesbaden, Germany), the anti‐type‐II collagen (II‐II6B3) antibody from NIH Hybridoma Bank (University of Iowa, Ames, USA), the anti‐SOX9 (C‐20) antibody from Santa Cruz Biotechnology (Heidelberg, Germany), the anti‐type‐I collagen (AF‐5610) antibody from Acris (Hiddenhausen, Germany) and the anti‐type‐X collagen (COL‐10) antibody from Sigma‐Aldrich. Secondary biotinylated antibodies and the ABC kit were from Vector Laboratories (Alexis Deutschland GmbH, Grünberg, Germany). The hIGF‐I Quantikine ELISA was purchased at R&D Systems and the type‐II, ‐I and ‐X collagen ELISAs at Antibodies‐Online (Aachen, Germany).
+ Open protocol
+ Expand
10

Chondrocyte Extracellular Matrix Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents were from Sigma (Munich, Germany) unless otherwise indicated. Recombinant FGF-2 (rFGF-2) and TGF-β3 were purchased at R&D Systems (Wiesbaden-Nordenstadt, Germany) and Peprotech (Rocky Hill, NJ, USA), respectively. The dimethylmethylene blue dye was from Serva (Heidelberg, Germany). The anti-SOX9 (C-20) antibody was from Santa Cruz Biotechnology (Heidelberg, Germany), the anti-aggrecan (BC-13) antibody from Abcam (Cambridge, UK), the anti-type-II collagen (AF-5710) and anti-type-I collagen (AF-5610) antibodies from Acris (Hiddenhausen, Germany), the anti-type-X collagen (COL-10) antibody from Sigma, and biotinylated secondary antibodies with ABC reagent from Vector Laboratories (Alexis Deutschland GmbH, Grünberg, Germany). The type-II collagen enzyme-linked immunosorbent assay (Arthrogen-CIA Capture ELISA kit) was from Chondrex (Redmond, WA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!