The largest database of trusted experimental protocols

Isotrak

Manufactured by Polhemus
Sourced in United States

The ISOTRAK is a lab equipment product designed for precise tracking and monitoring of motion and position. It utilizes electromagnetic technology to capture real-time 3D data on the position and orientation of objects within a defined measurement volume.

Automatically generated - may contain errors

5 protocols using isotrak

1

EEG Montage for Multimodal Neuroimaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
A single-channel (Cz; 10–20 International System) EEG montage was applied with a forehead ground and earlobe references1 (link). Bipolar EOG electrodes around the eyes and ECG electrodes on the chest were applied for later use in detecting corresponding artefacts in the MEG traces. Head shape and the location of head position indicator coils were digitized (Polhemus Isotrak, Polhemus Inc., VT, USA) for co-registration of MEG with anatomical T1-weighted MRI.
+ Open protocol
+ Expand
2

Multimodal Neuroimaging Protocol with MEG and MRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
MEG (Elekta Neuromag) was recorded using 306-channel at a sampling rate of 1000 Hz (online bandpass filter = 0.1–330 Hz). Channels were arranged as triplets (1 magnetometer and 2 gradiometers). Bipolar leads recorded blinks (VEOG), lateral eye movements (HEOG), and cardiac activity (ECG). Four head position indicator coils were placed on the scalp and their position was recorded using a 3D-digitizer (ISOTRAK; Polhemus, Inc., Colchester, VT). Head position was monitored throughout testing and corrected for using Neuromag MaxFilter software (http://imaging.mrc-cbu.cam.ac.uk/meg/Maxfilter_V2.2).
T1-weighted images were obtained for each participant using a Siemens TIM Trio 3 T MRI system with a multi-echo 3D MPRAGE sequence [TR/TE/TI = 2530/1.74, 3.6, 5.46, 7.32/1260 ms, flip angle = 7°, field of view (FOV) = 220 × 220 mm, 1 mm isotropic voxel size, 176 slices, GRAPPA acceleration factor = 2].
+ Open protocol
+ Expand
3

Magnetoencephalography Data Acquisition Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MEG data were obtained in a magnetically shielded room (Imedco AG, Hägendorf, Switzerland) using a a 306-channel whole-head MEG system (Elekta Neuromag) with a sampling rate of 1,000 Hz (online half-power band pass filter = 0.1–330 Hz). Bipolar leads were placed above and below the left eye (VEOG) and lateral to the outer canthi of both eyes (HEOG). Bipolar ECG leads were placed just below the left and right clavicle. Four head position indicator (HPI) coils were placed on the head and locations (relative to the nasion and preauricular points) were recorded using a 3D-digitizer (ISOTRAK; Polhemus, Inc., Colchester, VT). Head position was tracked continuously throughout the experiment.
+ Open protocol
+ Expand
4

Multimodal Neuroimaging Protocol for Brain Study

Check if the same lab product or an alternative is used in the 5 most similar protocols
MEG data were collected with a whole-head MEG system (CTF OMEGA System) consisting of 275 axial gradiometers. For each MEG session we first collected five minutes of empty room recordings, which we used to estimate noise covariance of the sensors (see below). Before the participant entering the magnetically shielded room, three marker coils were placed on the participant's head. Marker positions, nasion, left and right pre-auricular points, and the participant's head shape were recorded with a pen digitizer (Isotrak; Polhemus, Colchester, VT, USA), using a minimum of 500 points. Two electrooculogram electrodes were places above and below the left eye, to record eye blinks and eye movements during the MEG session. Two electrodes were placed across the plane of the chest to collect electrocardiographic signals, and a reference electrode was placed below the participant's collarbone. Each participant's MEG data and simultaneous electrooculographic and electrocardiographic signals were collected at a sampling frequency of 2400Hz. In conjunction with these data, we collected participants’ button responses using a Vpixx ResponsePixx button box system (VPixx Technologies, Saint-Bruno-de-Montarville, QC, Canada).
+ Open protocol
+ Expand
5

Simultaneous EEG and MEG Recordings

Check if the same lab product or an alternative is used in the 5 most similar protocols
EEG and MEG data were obtained simultaneously in a magnetically shielded room (Imedco AG, Hägendorf, Switzerland). Data were recorded using a low-impedance 60-electrode EEG array based on the 10-10 system and a 306-channel whole-head MEG system (Elekta Neuromag) with a sampling rate of 1000 Hz (online half-power bandpass filter=0.1-330 Hz). EEG recordings were referenced to the left mastoid. The right mastoid was used as ground (a separate electrode was also used to record right mastoid activity). Bipolar leads were placed above and below the left eye (VEOG) and lateral to the outer canthi of both eyes (HEOG). Bipolar ECG leads were placed just below the left and right clavicle. Four head position indicator (HPI) coils were placed between electrodes on the surface of the EEG cap, and locations (relative to the nasion and preauricular points) were recorded using a 3D-digitizer (ISOTRAK; Polhemus, Inc., Colchester, VT). Head position was tracked continuously throughout the experiment.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!