The largest database of trusted experimental protocols

3 protocols using new coccine

1

Synthesis of Functionalized Polymers and Ligands

Check if the same lab product or an alternative is used in the 5 most similar protocols
tert-Butanol
(≥99%), alcohol (EtOH, 99.7%), manganese(II) nitrate (50 wt
% aqueous solution), and nitric acid (HNO3, 65–68%)
were purchased from the Shanghai Chemical Reagent Company. Tetramethyl
orthosilicate (TMOS, 99.0%), methylene blue trihydrate (MB, 82%),
and hydrogen peroxide (H2O2, 30%) were purchased
from Adamas Reagent. Methanol (CH3OH, 99.5%) was purchased
from Sinopharm Chemical Reagent Co., Ltd. New coccine (75.0%) was
purchased from Sigma-Aldrich. Manganese acetate (Mn(CH3COO)2, 98%), rhodamine 6G (95%), and methyl orange (96%)
were purchased from Aladdin. Orange II sodium salt (>85%), p-benzoquinone (99.0%), and silicon dioxide (99.5%) were
purchased from Macklin. Orange G (96%) was purchased from Meryer. l-Ascorbic acid was purchased from TCI (Shanghai) Development
Co., Ltd. Synthesis of quaternized poly(2-vinylpyridine)-b-poly(ethylene oxide) (positively charged P2MVP128-b-PEO477, Mw/Mn = 1.1, Mw = 34.5k,
level of quaternization is ∼90%) is described in the previous
work.29 (link),30 (link),63 (link) The 1,3,5-tris(2,6-dicarboxypyridin-4-yloxymethyl)benzene
ligands (L3) were synthesized according to the literature.31 (link)
+ Open protocol
+ Expand
2

Carminic Acid Colorimetric Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Carminic acid (CA), Alizarin (ALI), New Coccine (NC), sodium azide and superoxide dismutase (SOD) from bovine erythrocytes were provided by Sigma-Aldrich whereas the aluminium-calcium complex of Carminic acid (referred as carmine, carminic lake or, simply, lake) was provided by Colores Naturales de Oaxaca (Oaxaca, Mexico). Ultrapure water was obtained from a Milli Q water purification system (Millipore, USA) while hydrochloric acid (HCl) and sodium hydroxide were acquired from Merck. All the chemicals and reagents were purchased at the highest purity available and used without further purification. Research grade (5.0) N 2 gas was used to decrease the oxygen partial pressure in the samples.
+ Open protocol
+ Expand
3

Quantitative Analysis of Synthetic Dyes

Check if the same lab product or an alternative is used in the 5 most similar protocols
New Coccine, Indigo Carmine, Erythrosine, Tartrazine, Sunset Yellow FCF, Fast Green FCF, Brilliant Blue FCF, Allura Red AC, Amaranth, Sudan II, Sudan IV, Dimethyl Yellow, Fast Garnet GBC, Para Red, Sudan Orange G, Sudan Red 7B, Sudan Red B and Sudan Red G were purchased from Sigma-Aldrich (St. Louis, MO, USA). Sudan I was purchased from Tokyo Chemical Industry (Tokyo, Japan). Sudan III was purchased from Kanto Chemical (Tokyo, Japan). Methanol of HPLC grade was obtained from Mallinckrodt (Paris, KY, USA). Dimethyl sulfoxide (DMSO), acetonitrile, and acetic acid of HPLC grade were obtained from Merck (Darmstadt, Germany). Ammonia acetate was from Nacalai Tesque (Kyoto, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!