The largest database of trusted experimental protocols

Uv 3600 plus

Manufactured by Hitachi
Sourced in Japan

The UV-3600 Plus is a high-performance UV-Vis-NIR spectrophotometer manufactured by Hitachi. It is designed to perform accurate and reliable measurements in the ultraviolet, visible, and near-infrared regions of the electromagnetic spectrum.

Automatically generated - may contain errors

2 protocols using uv 3600 plus

1

Dox@iRGD-Exos-131I Formulation and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
When 80 μg Dox and 740 MBq Na131I were added to 200 μg of iRGD-Exos, Dox@iRGD-Exos-131I were obtained via centrifugation (100,000×g, 90 min, 4 ℃). After washing several times with 1 × PBS, the supernatants were collected, and Dox@iRGD-Exos-131I were resuspended in 500 μL of 1 × PBS. The amount of free Dox in the supernatants was measured and calculated from the standard calibration curve based on the absorbance at λ = 485 nm measured by using an ultraviolet–visible (UV–Vis) spectrophotometer (UV-3600 plus, Hitachi, Japan). The loading efficiency (%) of Dox was calculated as follows [20 (link), 41 (link)]: A=(B-C)100%B.
where A is the loading efficiency (%) of Dox; B is the original weight of Dox; and C is the weight of Dox in the supernatants.
+ Open protocol
+ Expand
2

Synthetic Methodology for Fluorene-Based Organometallic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The preparative work was carried out under a nitrogen atmosphere using standard Schlenk techniques. Solvents used for reaction were freshly distilled under nitrogen from either sodium or calcium hydride prior to use. Reactants 6,9-bis(1,1'thiobis(ethane))decaborane (B 10 H 12 (Et 2 S) 2 ), 18 9,9-dimethyl-2-(2phenylethynyl)-9H-Fluorene 19 (1a) and 2,2'-(1,2-ethynediyl)bis[9,9dimethyl-9H-Fluorene] 20 (1c) were prepared according to literature methods. Other chemicals such as 2-iodo-9,9-dimethylfluorene and 2-bromo-9,9-diphenylfluorene were commercial products and were used as received. The NMR data were obtained on a Bruker DRX 400 spectrometer; chemical shifts are given with respect to CHCl 3 /CDCl 3 (δ 1 H = 7.26 ppm, δ 13 C = 77.00 ppm) and external BF 3 •Et 2 O (δ 11 B = 0 ppm). Mass spectral data were recorded on Micromass/Waters GCT premier with a high-resolution gas chromatography/time-of-flight mass spectrometer. Elemental analyses were performed on Elementar vario MICRO cube (Germany). The absorption and photoluminescence spectra were recorded on an UV-Vis-NIR spectrophotometer (Shimadzu UV-3600 Plus) and a fluorescence spectrophotometer (Hitachi F-4600) equipped with a high performance R928 photomultiplier detector.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!