Sadabs

Manufactured by Bruker
Sourced in United States

SADABS is a software program developed by Bruker for the empirical determination of absorption corrections in single-crystal X-ray diffraction experiments. It provides a robust and reliable method to account for the effects of sample absorption, improving the accuracy of the collected data.

Automatically generated - may contain errors

912 protocols using sadabs

1

Single Crystal X-Ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Suitable crystals for X-ray diffraction were mounted on a loop with protective oil, and X-ray data was collected on a Bruker APEX II CCD detector diffractometer using graphite monochromated MoKα radiation (λ = 0.71073 Å) and operated in a φ and ω scans mode. A semi empirical absorption correction was carried out using SADABS (Sheldrick, G. M. SADABS, Bruker AXS Inc., Madison, Wisconsin, USA, 2004). Data collection, cell refinement and data reduction were done with the SMART and SAINT programs (SMART and SAINT, Bruker AXS Inc., Madison, Wisconsin, USA, 2004).
The structures were solved by direct methods using SIR97 [35] (link) and refined by fullmatrix least-squares methods using the program SHELXL97 [36] using the winGX software package [37] (link). Non-hydrogen atoms were refined with anisotropic thermal parameters, except in cases of disorder where these specific atoms were refined as isotropic, whereas H-atoms were placed in idealized positions and allowed to refine riding on the parent C atom. Molecular graphics were prepared using ORTEP [38] (link).
+ Open protocol
+ Expand
2

Bruker X8 APEX Diffractometer Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker X8 APEX diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2009 ▸ ) Tmin = 0.589, Tmax = 0.746

9214 measured reflections

3582 independent reflections

2406 reflections with I > 2σ(I)

Rint = 0.040

+ Open protocol
+ Expand
3

Single Crystal X-Ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker SMART CCD 1K area-detector diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2012 ▸ ) Tmin = 0.701, Tmax = 0.746

27028 measured reflections

3964 independent reflections

3582 reflections with I > 2σ(I)

Rint = 0.021

+ Open protocol
+ Expand
4

Single Crystal X-ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker Kappa APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2004 ▸ ) Tmin = 0.948, Tmax = 0.955

14793 measured reflections

1809 independent reflections

1528 reflections with I > 2σ(I)

Rint = 0.023

+ Open protocol
+ Expand
5

Single Crystal X-ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.92, Tmax = 0.95

46817 measured reflections

5318 independent reflections

4636 reflections with I > 2σ(I)

Rint = 0.035

+ Open protocol
+ Expand
6

Crystal Structure Determination by X-ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2005 ▸ ) Tmin = 0.715, Tmax = 0.890

8297 measured reflections

3028 independent reflections

2686 reflections with I > 2σ(I)

Rint = 0.030

+ Open protocol
+ Expand
7

Crystal Structure Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker Kappa APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2004 ▸ ) Tmin = 0.981, Tmax = 0.985

10595 measured reflections

3454 independent reflections

1668 reflections with I > 2σ(I)

Rint = 0.039

+ Open protocol
+ Expand
8

Single Crystal X-ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker Kappa APEXII CCD diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2008 ▸ ) Tmin = 0.941, Tmax = 0.960

7690 measured reflections

3638 independent reflections

2447 reflections with I > 2σ(I)

Rint = 0.038

+ Open protocol
+ Expand
9

Single Crystal X-Ray Diffraction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker X8 APEX diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2009 ▸ ) Tmin = 0.670, Tmax = 0.746

25334 measured reflections

4082 independent reflections

3071 reflections with I > 2σ(I)

Rint = 0.031

+ Open protocol
+ Expand
10

CMOS Diffractometer for Crystal Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols

Bruker D8 VENTURE PHOTON 100 CMOS diffractometer

Absorption correction: multi-scan (SADABS; Bruker, 2014 ▸ ) Tmin = 0.90, Tmax = 0.95

11331 measured reflections

3063 independent reflections

2538 reflections with I > 2σ(I)

Rint = 0.031

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!