Rat igg2a kappa control pe

Manufactured by BD
Sourced in United States

Rat IgG2a Kappa Control PE is a laboratory reagent used for the detection and analysis of cells in flow cytometry. It serves as a control to establish baseline measurements and validate assay performance. The core function of this product is to provide a consistent, standardized reference sample for flow cytometry experiments.

Automatically generated - may contain errors

2 protocols using rat igg2a kappa control pe

1

Quantifying SVF cells in grafts

Check if the same lab product or an alternative is used in the 5 most similar protocols
Grafts from the fresh SVF gel group, 1-month-frozen SVF gel group, fresh fat group, and 1-month-frozen fat group were harvested at 1 month after transplantation. Samples were digested, and the SVF was assessed by flow cytometry. Briefly, 0.5 cc of graft tissues was minced with scissors and incubated in 0.075% collagenase buffer in a shaking water bath (37 °C, 30 min) for digestion. After neutralization and filtration, SVF cells were washed and stained with the following antibodies and corresponding isotype controls: anti-CD11b-PE (Miltenyi Biotec, Bergisch Gladbach, Germany), anti-F4/80-APC (eBioscience, Inc., CA, USA), rat IgG2a Control APC (BD Biosciences), and rat IgG2a Kappa Control PE (BD Biosciences). Samples were analyzed by flow cytometry (MACSQuant Analyzer 10; Miltenyi Biotec). Gating for each signal was set to eliminate 99.9% of the cells in the corresponding isotype control. Experiments were conducted in triplicate using 0.5-cc grafts collected from three mice in the same groups.
+ Open protocol
+ Expand
2

Phenotypic Analysis of ECFCs and ASCs

Check if the same lab product or an alternative is used in the 5 most similar protocols
For flow cytometry analysis, suspended ECFCs and ASCs were filtered, washed, and stained with the following antibodies and corresponding isotype controls: anti-CD45-Cy5 (Miltenyi Biotec, Bergisch Gladbach, Germany), anti-CD133-PE (eBioscience, Inc., CA, USA), anti-CD31-FITC (BD Biosciences), anti-CD105-FITC (BD Biosciences), rat IgG2a Kappa cy5 (BD Biosciences), and rat IgG2a Kappa Control PE (BD Biosciences). Samples and controls were analyzed with a MACSQuant Analyzer 10 (Miltenyi Biotec). Each channel was gated respective to the control samples.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!