All materials were used as received without further purification. The organic halide salts (FAI, MAI and phenylethylammonium iodide (PEAI) with purity of >99%) were purchased from GreatCell Solar Materials. PEDOT-PSS aqueous solution (Al 4083) was purchased from Heraeus Clevios. PbI2 (99.99%, trace metals basis) and PbBr2 (99.99%, trace metals basis) were purchased from TCI. SnI2 (99.999%, trace metals basis) was purchased from Alfa Aesar. SnF2 (99%), tin powders (<150 μm, 99.5%), CsI (99.999%), DMF (99.8% anhydrous), DMSO (99.9% anhydrous), formamidine sulfinic acid (FSA, ≥98%), chlorobenzene (99.8% anhydrous) were purchased from Sigma-Aldrich. The C60 was purchased from Nano-C. N4,N4 ′di(naphthalen-1-yl)-N4,N4 ′ -bis(4-vinylphenyl) biphenyl-4,4 ′ -diamine (VNPB, >95%) was purchased from Lumtec.
+ Open protocol
+ Expand
2

Perovskite Solar Cell Fabrication

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following materials were used: formamidinium
iodide (Sigma, >99%), PbI2 (Sigma, 99%), phenylethylammonium
iodide (Greatcell Solar Materials), anhydrous dimethylformamide (99.8%,
Acros), dimethylsulfoxide (99.7%, Acros), acetone (99.6%, Acros),
chlorobenzene (99.8%, Acros), isopropanol (99.5%, Acros), and d5-FAI (Cortecnet, 85% CD deuterated, 90% ND2 deuterated). d4-FAI and d3-PEAI were prepared by dissolving in heavy
water (1:40 mol/mol ratio), followed by evaporation. This yielded
∼50 and ∼70% deuterium on the FAI and PEAI, respectively.
+ Open protocol
+ Expand
3

Perovskite Solar Cell Material Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Titanium(IV) chloride (TiCl4,
CR), Tetrabutyl titanate (C16H36O4Ti, 98%), and hydrochloric acid (HCl 36–38%) were obtained
from Sinopharm Chemical Regent Co. Tin chloride (SnCl4,
98%) was purchased from McLean. Methylammonium iodide (MAI, 99.8%),
formamidinium iodide (FAI, 99.5%), methylammonium chloride (MACl,
99.9%), and lead iodide (PbI2, 99.99%) were purchased from
Xi’an Polymer Light Technology Corp. N,N-dimethylformamide (DMF, 99.9%), dimethyl sulfoxide (DMSO,
99.9%), and isopropanol (IPA, ≥99.7%) were purchased from Sigma-Aldrich.
Phenylethylammonium iodide (PEAI, 98%) were obtained from Greatcell
solar. Low temperature carbon paste was purchased from Shanghai MaterWin
New Materials Co.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!