The largest database of trusted experimental protocols

Revolution evo ct system

Manufactured by GE Healthcare
Sourced in Switzerland

The Revolution EVO CT system is a computed tomography (CT) imaging device manufactured by GE Healthcare. It is designed to capture high-quality images of the internal structures of the human body for diagnostic purposes.

Automatically generated - may contain errors

2 protocols using revolution evo ct system

1

Dynamic Lung Imaging in ARDS

Check if the same lab product or an alternative is used in the 5 most similar protocols
High-resolution CT imaging was performed for assessment of regional aeration and strain. After stabilization of ARDSNet or maximal compliance PEEP for 15 min, CT images (GE Discovery MI PET/CT with Revolution EVO CT system, tube current of 49 mAs and voltage of 120 kVp) were acquired dynamically during breathing. Segmentation of global lung volumes was performed semi-automatically with exclusion of large-to-intermediate bronchi and vessels. CT images were reconstructed with standard convolution kernel and filtered back projection resulting in a matrix of 512 × 512 × 112 voxels of 0.977 × 0.977 × 2.5 mm3 [29 (link)].
+ Open protocol
+ Expand
2

Evaluating Lumbar Disc Height Changes

Check if the same lab product or an alternative is used in the 5 most similar protocols
In vivo clinical CT scans of the lumbar spine were acquired using a Revolution EVO CT system (GE Medical Systems, Switzerland) to evaluate disc height changes over time. Scans were acquired preoperatively, immediately postoperatively (W0), 4 weeks postinjury (W4), W8, and after euthanasia at W12. Sheep were sedated and anesthetized before in vivo clinical CT imaging as described above (Section 2.4). The CT images were obtained with a slice thickness and spacing of 0.625 and 0.312 mm, respectively. Tube voltage was 120 kVp and the tube current was 300 mA. Disc height was measured by a blinded observer using Amira software (Amira 6.5, FEI SAS, Thermo Fisher Scientific) as previously described.
48 (link) Briefly, lumbar vertebrae were semi‐automatically segmented, and then the shortest distance between each point on the cranial IVD extremity and the caudal IVD extremity was measured for each IVD. The average disc height was calculated as the arithmetic mean of all points along an individual IVD, which was approximately 5000 points. Postoperative disc heights were expressed as a percentage of the preoperative disc heights. Therefore, a relative disc height of less than 100% postoperatively would represent a disc height loss when compared to preoperative values.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!