The largest database of trusted experimental protocols

Astra v 5.3.4.14 software

Manufactured by Wyatt Technology

Astra (v. 5.3.4.14) is a software product developed by Wyatt Technology. It serves as a data analysis and processing tool for laboratory equipment.

Automatically generated - may contain errors

2 protocols using astra v 5.3.4.14 software

1

Alginate Characterization by SEC-MALLS

Check if the same lab product or an alternative is used in the 5 most similar protocols
We made SEC-MALLS measurements on an HPLC system equipped with three straight connected columns: TSKgel G6000PWXL, G5000PWXL, and G4000PWXL (7.5 mm i.d. × 600 mm, Tosoh Corporation, Tokyo, Japan). The column outlet was connected to a Dawn Heleos-II multiangle laser light scattering photometer (Wyatt Technology Corp., Santa Barbara, USA) (λ = 658 nm) which was connected to an Optilab rEX differential refractometer (Wyatt Technology Corp.). The mobile phase was 0.05 M Na2SO4/0.01 M EDTA (pH 6). The flow rate was 0.7 mL/min. The injection volume was 100 μL, and the sample concentration was 0.2 or 0.4 % for appropriate light scattering intensity. The sample solution was filtered with a 0.22 μm filter before injection. The value of the refractive index increment (δnc) for the alginate was 0.150 mL/g, according to a previous report.13) (link) Data from the light scattering and the differential refractometers were collected and processed using Astra (v. 5.3.4.14) software (Wyatt Technology Corp.).
+ Open protocol
+ Expand
2

SEC-MALS Analysis of Purified PGA

Check if the same lab product or an alternative is used in the 5 most similar protocols
SEC-MALS measurements were performed using an HPLC system equipped with three straight connected columns: OHpak SB-807HQ, OHpak SB-806HQ, and OHpak SB-805HQ (Showa Denko, Tokyo, Japan). Purified PGA samples were dissolved in deionized water at a final concentration of 1 mg mL -1 unless stated otherwise. The column outlet was connected to a Dawn Heleos-II multiangle laser light scattering photometer (Wyatt Technology Corp., Santa Barbara, CA, USA) (λ = 658 nm), which was connected to an Optilab rEX differential refractometer (Wyatt Technology Corp.). Prior to analysis, the samples were filtered through polyethersulfone syringe filters with a pore size of 0.45 µm (ADVANTEC, Tokyo, Japan). The analysis conditions were as follows: isocratic elution with 200 mmol L -1 KNO3 at 40°C; flow rate, 0.7 mL min -1 ; and PGA sample injection volume, 50 µL. Data from the light scattering and differential refractometers were collected and processed using Astra (v. 5.3.4.14) software (Wyatt Technology Corp.) [16] .
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!