The MK118 is a laboratory equipment designed for automated pipetting and liquid handling. It features precise volume control, programmable liquid handling protocols, and compatibility with a wide range of labware. The core function of the MK118 is to perform accurate and reproducible liquid transfers, enabling efficient sample preparation and assay workflows.

Automatically generated - may contain errors

4 protocols using mk118

1

Bone Turnover Markers Serum Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
ELISA kits were used to measure the serum levels of human bone Alkaline Phosphatase (bALP; Cusabio, CSB-E09033h, Houston, TX, USA), procollagen I N-terminal Peptide (PINP; Cusabio, CSB-E11226h), carboxyterminal propeptide of type I procollagen (PICP; Cusabio, CSB-E08079h), cross linked N-telopeptide of type I collagen (NTX; Cusabio, CSB-E09233h), and cross linked C-telopeptide of type I collagen (CTX; Novusbio, NBP2-69073, Centennial, CO, USA).
EIA kits were used to measure serum levels of human osteocalcin in the undercaboxylated (unOC) and carboxylated (cOC) form (Takara, Shiga, Japan, MK-118 and MK-111, respectively).
+ Open protocol
+ Expand
2

Bovine Osteocalcin Concentration Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cows were randomly selected within KET and CON groups, respectively, for the analysis of cOC (n = 16 in KET and n = 15 in CON) and ucOC (n = 17 in KET and n = 18 in CON) concentrations, and plasma samples from BW–1 and BW1 were used. The analysis was performed using cOC and ucOC ELISA kits (MK111 and MK118, Takara, Shiga, Japan), and the intra-and inter-assay coefficients of variation (CV) were 4.3 and 3.6% for cOC and 5.9 and 7.8% for ucOC, respectively.
+ Open protocol
+ Expand
3

Serum Biomarkers Assessment Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood sample were harvested in the morning after at least 8 hours fasting. Serum was gathered after centrifugation at 3,000 r/min for 10 minutes. Serum ucOC were assayed by ELISA (MK118, Takara Bio Inc, Japan), with the intra assay coe cient of variation of 4.58%-6.66% and the inter assay coe cient of variation of 5.67%-9.87%. Serum cOC were measured by ELISA (MK111, Takara Bio Inc, Japan), with the intra assay coe cient of variation of 3.3%-4.8%, the inter assay coe cient of variation of 0.7%-2.4%.
Serum calcium (Ca), phosphorus (Pi), and alkaline phosphatase (ALP) measurements were performed by a Beckman Automatic Biochemical Analyzer (AU5800, Beckman Coulter, Indianapolis, IN, USA). Serum OC, β-isomer of C-terminal telopeptides of type I collagen (β-CTX), N-terminal prepeptide of type 1 procollagen (P1NP) were measured by electrochemiluminescence immunoassay (Roche Cobas e601, Mannheim, Germany). Parathyroid hormone (PTH) was measured using chemiluminescence (Siemens ADVIA Centaur, Munich, Germany). 25hydroxyvitamin D (25OHD) was measured by electrochemiluminescence immunoassay (Roche Cobas e601, Mannheim, Germany). Creatinine (Cr) was measured by an automated Roche electrochemiluminescence system (E170; Roche Diagnostics, Basel, Switzerland). All measurements were completed by central laboratory of PUMCH.
+ Open protocol
+ Expand
4

Hormone Profiling in Euthanized Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood was collected from the inferior vena cava at the time of euthanasia, and plasma was stored at −80°C until analysis. All analyses were performed in duplicate. Plasma insulin, and undercarboxylated osteocalcin were measured by ELISA (80-INSRT-E01 ALPCO, Salem, NH and MK118 Takara Bio USA, Mountain View, CA respectively); plasma glucose was measured using a colorimetric assay (TR15421, Thermo Fisher Scientific, Waltham, MA). Follicle stimulating hormone (FSH) was measured by MILLIPLEX map Rat Pituitary Panel kit, EMD Millipore product # RPTMAG-86K.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!