3 protocols using chirascan ecd spectrometer

1

Spectroscopic Analysis of Natural Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were determined using a SEEWE SGW-2 digital polarimeter. ECD data were recorded on an Applied Photophysics Chirascan ECD spectrometer. An HRESI-MS analysis was obtained using a Bruker Impact II mass spectrometer. The 1D and 2D NMR spectra were taken on either a BURKER 400 NMR or a Varian 600 NMR spectrometer. The preparative HPLC experiments were conducted on a Shimadzu LC-6AD packed with an SPD-10A detector and a reversed-phase C18 column (Shim-pack PREP-ODS (H). Kit, 20 × 250 mm, 5 μm). Silica gel (200−300 mesh, Qingdao Haiyang Chemical Co. Ltd., Qingdao, China), and ODS (45 μm, YMC Co. Ltd., Kyoto, Japan) were used for column chromatography (CC). HPLC grade Acetonitrile (MeCN) was used for preparative HPLC experiments, and other solvents were of analytical grade.
+ Open protocol
+ Expand
2

Comprehensive Analytical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotation was measured on a Rudolph Research Analytical Autopol IV automatic polarimeter (MeOH, c in g/100 mL). The ECD spectrum was recorded in MeOH using an Applied Photophysics Chirascan ECD spectrometer. UV spectra were recorded using a Thermo Scientific Evolution 260 Bio spectrophotometer (Shanghai, China, designed in the USA). IR spectra were obtained on a Thermo Scientific Nicolet iS5 FT-IR spectrophotometer (Madison, WI, USA). NMR spectra were recorded on a Bruker Avance III NMR spectrometer with a CryoProbe (Germany). The proton (1H) and carbon (13C) frequencies are 600.2 and 150.9 MHz, respectively. Chemical shifts (δ) in ppm were referenced using the corresponding solvent signals: δH at 2.05 and δC at 29.92 for acetone-d6. Off-line FID processing was conducted with the Bruker TopSpin 3.2 software. HRESIMS data were obtained using a Waters SYNAPT (Milford, MA, USA) mass spectrometer. Silica gel 60, particle size 0.035−0.070 mm, supplied by Fluka, Switzerland (220−440 mesh), and silica gel, 230−400 mesh (Sorbent Technologies, GA, USA) were used for column chromatography. Analytical TLC analysis was carried out on silica gel plates (250 μm, 250 μM with UV254, Sorbent Technologies). Sephadex LH-20–100 was purchased from Sigma Chemical Company, USA. All procedures were carried out at room temperature using organic solvents of analytical grade (Sigma, USA).
+ Open protocol
+ Expand
3

Spectroscopic Analysis of Natural Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a JASCO P-2000 polarimeter (JASCO, Easton, MD, USA). All UV and ECD spectra were recorded with a Chirascan ECD spectrometer (Applied Photophysics, Leatherhead, UK). IR spectra were recorded on a JASCO FT/IR-4200 spectrometer. NMR spectra were acquired on a JEOL GSX 400 (JEOL, Tokyo, Japan) and AVANCE-600 NMR spectrometer (Bruker, Billerica, MA, USA). All HRESIMS data were measured on a Waters Xevo G2 QTOF mass spectrometer (Waters Co., Milford, MA, USA). Column chromatography was performed with Diaion HP-20 (Mitsubishi Chemical Industries Ltd., Tokyo, Japan) and Sephadex LH-20 (25–100 μm, GE Health care, IL, USA). Thin layer chromatography (TLC) was carried out using Kieselgel 50 F254 coated normal-phase silica gel TLC plates (Merck, Darmstadt, Germany). The preparative HPLC system was equipped with a G-321 pump (Gilson, Middleton, WI, USA), a G-151 UV detector (Gilson) and a YMC-Triart C18 column (250 mm × 10 mm I.D., 5 μm, YMC Co., Ltd., Koyoto, Japan). All solvents were purchased from Daejung Chemicals & Metals CO. Ltd. (Siheung, Korea).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!