The largest database of trusted experimental protocols

Synergi c18 150 25 10 um

Manufactured by Phenomenex

Synergi C18 150*25*10 μm is a reverse-phase high-performance liquid chromatography (HPLC) column. It features a C18 stationary phase with 150 mm length, 2.5 mm internal diameter, and 10 μm particle size. This column is designed for the separation and analysis of a wide range of organic compounds.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using synergi c18 150 25 10 um

1

Synthesis of Pyrazolo-pyrimidine Derivative

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 49

[Figure (not displayed)]

To a mixture of N-[1-[4-(chloromethyl)phenyl]-3-(difluoromethyl)pyrazol-4-yl]-5-[(1R)-2-oxa-5-azabicyclo[2.2.1]heptan-5-yl]pyrazolo[1,5-a]pyrimidine-3-carboxamide (200 mg, 400 umol, Intermediate AUO) and 2-(2,6-dioxo-3-piperidyl)-4-(4-piperidylmethylamino)isoindoline-1,3-dione (162 mg, 400 umol, HCl salt, Intermediate AJI) in THF (5 mL) and DMF (1 mL) was added K2CO3 (165 mg, 1.20 mmol). The reaction mixture was stirred at 60° C. for 12 hours. On completion, the reaction mixture was filtered and concentrated in vacuo. The residue was purified by prep-HPLC (column: Phenomenex Synergi C18 150*25*10 um; mobile phase: [water (0.225% FA)-ACN]; B %: 19%-49%, 10 min) to give the title compound (35.1 mg, 9% yield) as yellow solid. 1H NMR (400 MHz, DMSO-d6) δ 11.09 (s, 1H), 9.61 (d, J=4.4 Hz, 1H), 8.96 (d, J=2.8 Hz, 1H), 8.80 (d, J=7.6 Hz, 1H), 8.34-8.27 (m, 1H), 7.78 (d, J=8.4 Hz, 2H), 7.61-7.50 (m, 1H), 7.44 (d, J=8.4 Hz, 2H), 7.30-7.00 (m, 3H), 6.93-6.43 (m, 2H), 5.32-5.01 (m, 2H), 4.78 (d, J=13.6 Hz, 1H), 3.83 (s, 1H), 3.76-3.61 (m, 2H), 3.53-3.45 (m, 4H), 3.25-3.18 (m, 2H), 2.94-2.79 (m, 3H), 2.63-2.53 (m, 2H), 2.08-1.86 (m, 4H), 1.73-1.62 (m, 2H), 1.62-1.52 (m, 1H), 1.33-1.18 (m, 2H); LC-MS (ESI+) m/z 834.4 (M+H)+.

+ Open protocol
+ Expand
2

Synthesis and Purification of 3-06 Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 41

[Figure (not displayed)]

To a solution of 3-05 (80 mg, 149 μmol) in methanol (1 mL) was added lithium borohydride (13 mg, 600 μmol) at 0° C. The mixture was stirred at 0° C. for 1 hour then poured into a mixture of water (15 ml) and 1 N hydrochloric acid (10 mL). The mixture was extracted with ethyl acetate (10 mL*2). The combined organic phase was washed with brine (20 ml), dried over anhydrous sodium sulfate, filtered, and concentrated under reduced pressure. The residue was purified by prep-HPLC (column: Phenomenex Synergi C18 150*25*10 um; mobile phase: [water (0.1% TFA)−ACN]; B %: 28%-55%, 12 min) to afford 3-06 (51 mg, 67% yield) as a white solid. LCMS for 3-06: RT=2.329 min, m/z 508.3 [M+H]+.

+ Open protocol
+ Expand
3

Synthesis of Pyrazolo-pyrimidine Derivative

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 49

[Figure (not displayed)]

To a mixture of N-[l-[4-(chloromethyl)phenyl]-3-(difluoromethyl)pyrazol-4-yl]-5-[(1R)-2-oxa-5-azabicyclo[2.2.1]heptan-5-yl]pyrazolo[1,5-a]pyrimidine-3-carboxamide (200 mg, 400 umol, Intermediate AUO) and 2-(2,6-dioxo-3-piperidyl)-4-(4-piperidylmethylamino)isoindoline-1,3-dione (162 mg, 400 umol, HCl salt, Intermediate AJI) in THF (5 mL) and DMF (1 mL) was added K2CO3 (165 mg, 1.20 mmol). The reaction mixture was stirred at 60° C. for 12 hours. On completion, the reaction mixture was filtered and concentrated in vacuo. The residue was purified by prep-HPLC (column: Phenomenex Synergi C18 150*25*10 um; mobile phase: [water (0.225% FA)-ACN]; B %: 19%-49%,10 min) to give the title compound (35.1 mg, 9% yield) as yellow solid. 1H NMR (400 MHz, DMSO-d6) δ 11.09 (s, 1H), 9.61 (d, J=4.4 Hz, 1H), 8.96 (d, J=2.8 Hz, 1H), 8.80 (d, J=7.6 Hz, 1H), 8.34-8.27 (m, 1H), 7.78 (d, J=8.4 Hz, 2H), 7.61-7.50 (m, 1H), 7.44 (d, J=8.4 Hz, 2H), 7.30-7.00 (m, 3H), 6.93-6.43 (m, 2H), 5.32-5.01 (m, 2H), 4.78 (d, J=13.6 Hz, 1H), 3.83 (s, 1H), 3.76-3.61 (m, 2H), 3.53-3.45 (m, 4H), 3.25-3.18 (m, 2H), 2.94-2.79 (m, 3H), 2.63-2.53 (m, 2H), 2.08-1.86 (m, 4H), 1.73-1.62 (m, 2H), 1.62-1.52 (m, 1H), 1.33-1.18 (m, 2H); LC-MS (ESI+) m/z 834.4 (M+H)+.

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!