Energy filter tem libra 120

Manufactured by Zeiss
Sourced in Germany

The Energy Filter TEM Libra-120 is a transmission electron microscope (TEM) accessory designed by Zeiss. It is used to filter and select specific energy levels of electrons in the microscope's imaging system, allowing for improved contrast and resolution of samples.

Automatically generated - may contain errors

4 protocols using energy filter tem libra 120

1

Transmission Electron Microscopy of hUC-MSC-EVs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freshly isolated hUC-MSC-EVs in 150 μl of 1xPBS suspension were loaded onto carbon-coated copper grids (Ted Pella, USA) and incubated for 10 min. The grid was blotted with filter paper and stained with 2% uranyl acetate (Ted Pella, USA) for 1 min. Excessive uranyl acetate was removed, and the grid was let dry for 15 min before viewing using Energy Filter TEM Libra-120 (Carl Zeiss AG, Germany).
+ Open protocol
+ Expand
2

Ultrastructural Analysis of hUC-MSC-EV

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freshly isolated hUC-MSC-EV in 150µl of 1xPBS suspension were loaded onto carbon-coated copper grids (Ted Pella, USA) and incubated for 10 minutes. The grid was blotted with lter paper and stained with 2%
uranyl acetate (Ted Pella, USA) for 1 minute. Excessive uranyl acetate was removed and the grid was let dry for 15 min before viewing using Energy Filter TEM Libra-120 (Carl Zeiss AG, Germany).
+ Open protocol
+ Expand
3

Transmission Electron Microscopy of hUC-MSC-EVs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freshly isolated hUC-MSC-EVs in 150µl of 1xPBS suspension were loaded onto carbon-coated copper grids (Ted Pella, USA) and incubated for 10 minutes. The grid was blotted with lter paper and stained with 2% uranyl acetate (Ted Pella, USA) for 1 minute. Excessive uranyl acetate was removed, and the grid was let dry for 15 min before viewing using Energy Filter TEM Libra-120 (Carl Zeiss AG, Germany).
+ Open protocol
+ Expand
4

Transmission Electron Microscopy of hUC-MSC-EVs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freshly isolated hUC-MSC-EVs in 150µl of 1xPBS suspension were loaded onto carbon-coated copper grids (Ted Pella, USA) and incubated for 10 minutes. The grid was blotted with lter paper and stained with 2% uranyl acetate (Ted Pella, USA) for 1 minute. Excessive uranyl acetate was removed, and the grid was let dry for 15 min before viewing using Energy Filter TEM Libra-120 (Carl Zeiss AG, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!