The largest database of trusted experimental protocols

X bridge 150 25 5 μm column

Manufactured by Waters Corporation

The X bridge 150x25 5 μM column is a laboratory equipment product manufactured by Waters Corporation. It is a chromatographic column designed for analytical applications. The column has dimensions of 150 mm length and 25 mm internal diameter, and the packing material has a particle size of 5 micrometers.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using x bridge 150 25 5 μm column

1

Synthesis of 5-(2-Furyl)isoxazol-3-yl Azetidine Derivative

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 98

[Figure (not displayed)]

To a solution of 5-(2-furyl)isoxazole-3-carboxylic acid (140 mg, 0.78 mmol) and N,N,N′,N′-tetramethyl-O-(1H-benzotriazol-1-yl)uronium hexafluorophosphate (356 mg, 0.94 mmol) in N,N′-dimethylformamide (3 mL) was added diisopropylethylamine (303 mg, 2.34 mmol) and 3-phenylazetidine hydrochloride (146 mg, 0.86 mmol). The mixture was stirred at 15° C. for 2 h. The mixture was purified by prep-HPLC (Waters X bridge 150×25 5 μM column; 35-70% acetonitrile in a 10 mM ammonium acetate solution in water, 10 min gradient) to afford [5-(2-furyl)isoxazol-3-yl]-(3-phenylazetidin-1-yl)methanone (0.086 g, 0.29 mmol, 37%) as a brown solid. 1H NMR (400 MHz, Chloroform-d) δ 7.59 (s, 1H), 7.41-7.35 (m, 4H), 7.31 (br. d, J=7.0 Hz, 1H), 6.95 (d, J=3.5 Hz, 1H), 6.89 (s, 1H), 6.56 (dd, J=1.8, 3.5 Hz, 1H), 5.02 (t, J=9.6 Hz, 1H), 4.68-4.61 (m, 2H), 4.32-4.26 (m, 1H), 4.01-3.92 (m, 1H); LCMS (ESI) m/z: 295.0 [M+H]+.

+ Open protocol
+ Expand
2

Synthesis of 5-(2-Furyl)isoxazole Derivative

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 103

[Figure (not displayed)]

To a solution of 5-(2-furyl)isoxazole-3-carboxylic acid (0.100 g, 0.56 mmol) and N,N,N′,N′-tetramethyl-O-(1H-benzotriazol-1-yl)uronium hexafluorophosphate (0.254 g, 0.67 mmol) in N,N′-dimethylformamide (3 mL) was added diisopropylethylamine (0.216 g, 1.67 mmol) and 3-benzylazetidine hydrochloride (0.113 g, 0.61 mmol). The mixture was stirred at 15° C. for 1 h and then directly purified by prep-HPLC (Waters X bridge 150×25 5 μM column; 35-75% acetonitrile in a 10 mM ammonium acetate solution in water, 10 min gradient) to give (3-benzylazetidin-1-yl)-[5-(2-furyl)isoxazol-3-yl]methanone (0.062 g, 0.20 mmol, 36%) as a yellow solid. 1H NMR (400 MHz, Chloroform-d) δ 7.57 (s, 1H), 7.31 (d, J=7.6 Hz, 2H), 7.26-7.22 (m, 1H), 7.18 (d, J=7.2 Hz, 2H), 6.94 (d, J=3.4 Hz, 1H), 6.85 (s, 1H), 6.56 (dd, J=1.7, 3.3 Hz, 1H), 4.68-4.62 (m, 1H), 4.33-4.26 (m, 2H), 3.95 (dd, J=4.7, 10.8 Hz, 1H), 3.05-2.97 (m, 3H); LCMS (ESI) m/z: 309.0 [M+H]+.

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!