The largest database of trusted experimental protocols

Genesig easy rna internal extraction control

Manufactured by Primerdesign
Sourced in United Kingdom

The GenesigⓇ Easy RNA Internal extraction control is a laboratory reagent designed to monitor the RNA extraction process. It is used to verify the efficiency of RNA extraction and to identify potential inhibition of the reverse transcription and/or amplification steps.

Automatically generated - may contain errors

2 protocols using genesig easy rna internal extraction control

1

Maxwell RSC Viral RNA Extraction

Check if the same lab product or an alternative is used in the 5 most similar protocols
RNA was extracted using the Maxwell RSC Viral Total Nucleic Acid Purification Kit (Promega UK Ltd., Southampton, UK) according to manufacturer's instructions. Briefly, a Class 1 microbiological safety cabinet (MSC) within a containment level 3 laboratory, 200 µl of sample was added to 223 µl of prepared lysis solution (including 5 µl per reaction of Genesig Easy RNA Internal extraction control, Primerdesign Ltd, Chandler's Ford, UK). Samples were then inactivated for 10 min at room temperature within the MSC and 10 min at 56 °C on a heat block before automated RNA extraction using a Maxwell RSC 48 Instrument (Promega UK Ltd., Southampton, UK). RNA was eluted in 50 µl of NFW. In the case of saliva, RNA was extracted from 200 µl of saliva diluted 1:20, as saliva volume was insufficient unless a dilution was performed.
+ Open protocol
+ Expand
2

SARS-CoV-2 RNA Extraction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
In a class 1 microbiological safety cabinet within a containment level 3 laboratory, 200 μL of sample was added to 223 μL of prepared lysis solution (including 5 μL per reaction of Genesig Easy RNA Internal extraction control; Primerdesign Ltd, Chandler's Ford, UK). Samples were then inactivated for 10 minutes at room temperature within the microbiological safety cabinet and 10 minutes at 56°C on a heat block before automated RNA extraction using a Maxwell RSC48 Instrument (Promega UK Ltd, Southampton, UK). RNA was eluted in 50 μL of nuclease-free water.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!