The largest database of trusted experimental protocols

Scrubbergen software

Manufactured by Horiba
Sourced in France

ScrubberGen is a software tool developed by Horiba for analyzing and optimizing the performance of gas scrubber systems. The software provides functionalities for modeling, simulating, and evaluating the efficiency of gas scrubbers used in various industrial applications.

Automatically generated - may contain errors

2 protocols using scrubbergen software

1

SPR Analysis of Rituximab Binding

Check if the same lab product or an alternative is used in the 5 most similar protocols
Antigen-antibody interactions were analyzed using an SPRi label-free interaction analysis platform, OpenPlex (HORIBA). The antigen, CD20 (Sino Biological, 11,007-H34E-B), was immobilized on the surface of a CS-HD biochip (HORIBA) with the amine coupling method. Neutral and acid-treated rituximab solutions were diluted into 20 mM citrate-phosphate buffer at pH 7.0 (running buffer) to 5 nM. The association was recoded at a rate of 50 μl/min for 180 s. The dissociation was measured by flowing running buffer alone for 540 s, followed by injecting 100 mM Gly-HCl at pH 3.2 for 60 s to regenerate the biochip. The experiments were performed at room temperature, and the reflectivity variation (%) in ligand spots was calculated by subtracting the signals of untreated areas on the chip surface. The collected data were analyzed using the ScrubberGen software (HORIBA).
+ Open protocol
+ Expand
2

SPRi Analysis of Protein Binding

Check if the same lab product or an alternative is used in the 5 most similar protocols
Surface plasmon resonance imaging (SPRi) analyses were performed using an SPRi system OpenPlex (HORIBA France, Palaiseau, France) according to a previous report.18 Briefly, 10 µM protein samples and normal human IgG (Sigma‐Aldrich) in PBS were spotted onto an SPRi‐Biochip (HORIBA France) at 10 nl/spot using a DNA Array Spotter (HORIBA Ltd., Kyoto, Japan). The reflectivity of each spot in response to 2.4 µM analyte samples diluted in running buffer (PBS with 0.2% BSA and 0.02% Tween20) was recorded, and the percentage change in reflectivity (%ΔR) was calculated by subtracting the background signal. Data were processed using ScrubberGen software (HORIBA France).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!