The largest database of trusted experimental protocols

Tsk gel α 2500

Manufactured by Tosoh
Sourced in Japan

The TSK gel α-2500 is a size exclusion chromatography column designed for the separation and analysis of macromolecules. It utilizes a porous polymer gel to facilitate the separation of samples based on their molecular size and shape.

Automatically generated - may contain errors

3 protocols using tsk gel α 2500

1

Gel Permeation Chromatography Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GPC analysis was performed at Toray Research Center (Tokyo, Japan). The purified sample (1 mg) was dissolved in 1 mL of dimethyl formamide (DMF) containing 50 mM lithium chloride (LiCl), and 200 μL of the sample was subjected to GPC. The molecular mass was estimated using a high-performance liquid chromatograph equipped with a refractive index detector (RI-8020; TOSOH, Tokyo, Japan), and TSK gel α-4000 and TSK gel α-2500 columns (7.8 mm × 30 cm; TOSOH, Tokyo, Japan), which were connected directly. DMF containing 50 mM LiCl was used as the solvent at a flow rate of 0.7 mL/min and the column temperature was maintained at 23 °C. The eluted sample was used for molecular mass determination, with a calibration curve obtained using standard polystyrene kits (PSt Quick E and F; TOSOH, Tokyo, Japan).
+ Open protocol
+ Expand
2

Gel Permeation Chromatography Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GPC analysis was performed at Toray Research Center (Tokyo, Japan). The puri ed sample (1 mg) was dissolved in 1 mL of dimethyl formamide (DMF) containing 50 mM lithium chloride (LiCl), and 200 μL of the sample was subjected to GPC. The molecular mass was estimated using a high-performance liquid chromatograph equipped with a refractive index detector (RI-8020; TOSOH, Tokyo, Japan), and TSK gel α-4000 and TSK gel α-2500 columns (7.8 mm × 30 cm; TOSOH, Tokyo, Japan), which were connected directly. DMF containing 50 mM LiCl was used as the solvent at a ow rate of 0.7 mL/min and the column temperature was maintained at 23°C. The eluted sample was used for molecular mass determination, with a calibration curve obtained using standard polystyrene kits (PSt Quick E and F; TOSOH, Tokyo, Japan).
+ Open protocol
+ Expand
3

GPC Analysis of Polymer Molecular Mass

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GPC analysis was performed by Torey Research Center (Japan). The puri ed sample (1 mg) was dissolved in 1 mL of dimethyl formamide (DMF) containing 50 mM lithium chloride, and 200 μL of the sample was subjected to GPC. The molecular mass was estimated using a high-performance liquid chromatograph equipped with a refractive index detector (RI-8020; TOSOH, Japan), and TSK gel α-4000 and TSK gel α-2500 columns (7.8 mm × 30 cm; TOSOH), which were connected directly. DMF containing 50 mM lithium chloride was used as the solvent at a ow rate of 0.7 mL/min and the column temperature was maintained at 23°C. The eluted sample was used for molecular mass determination, with a calibration curve obtained using standard polystyrene kits (PSt Quick E and F; TOSOH). 13
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!