Gsi viewer software

Manufactured by GE Healthcare
Sourced in United States

GSI viewer software is a tool for visualization and analysis of medical images. It provides a platform for healthcare professionals to view and interpret diagnostic images, such as X-rays, CT scans, and MRI scans. The software offers basic image manipulation and measurement capabilities to assist in the assessment of medical conditions.

Automatically generated - may contain errors

4 protocols using gsi viewer software

1

Dual-Energy CT Imaging for Gemstone Spectral Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data acquisitions were performed using single-source DECT in gemstone spectral imaging (GSI) mode with a fast tube voltage switching between 80 and 140 kVp (Revolution CT, GE Healthcare, Waukesha, WI, United States). Intravenous non-ionic contrast was given at 1.0 mL/kg. Routine soft tissue and bone windows were read. Standard multiplanar reconstructions and panoramic reconstructions were made. In addition, two types of images were obtained from the reconstruction of DECT imaging automatically with GSI viewer software (GE Healthcare) for each patient: The iodine-based and water-based material decomposition (MD) images (Figure 1).
+ Open protocol
+ Expand
2

Image Reconstruction Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
The raw data were reconstructed at 0.625 mm section thickness using 80% ASIR-V (IR 80% + FBP 20%) and DLIR algorithm at three selectable strength levels (low, DLIR-L; medium, DLIR-M; high, DLIR-H) graded by noise reduction capability. All reconstructions used standard kernel. All reconstructed images were processed into VMI at 50 keV using GSI Viewer software (Advantage Workstation, version 4.7, GE Healthcare).
+ Open protocol
+ Expand
3

Dual-Energy CT Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All patients underwent CT examinations (non-enhanced and dual-phasic contrast-enhanced scans) on a Discovery CT750HD scanner (GE Healthcare, WI). The non-enhanced scanning was performed first with the conventional helical mode at a tube voltage of 120kVp; tube current, 180mA; helical pitch, 1.375. A 80–100ml (1.35 ml/kg of body weight) nonionic iodinated contrast material (Iopamidol, 370 mg/ml; Shanghai Bracco Sine Phamaceutical Co. Ltd., China) was administrated at a rate of 4.0ml/s by using a power injector, and the dual-phasic enhancement scan delay times were 35 seconds at AP and 90 seconds at VP after the beginning of contrast medium injection. The contrast-enhanced scans were carried out with the dual energy spectral CT mode with fast tube voltage switching between 80kVp and 140kVp on adjacent views during a single rotation. The other DECT parameters were the following: tube rotation time, 0.6 seconds; tube current, 600mA; helical pitch, 1.375; field of view, 500mm; collimation, 40mm; and slice thickness and interval for axial images, 5mm/5mm. Two types of images were obtained from the reconstruction of DECT imaging automatically with GSI viewer software (GE Healthcare) for each patient: the iodine-based and water-based material decomposition images and a set of monochromatic images at energies ranging from 40 to 140keV.
+ Open protocol
+ Expand
4

Imaging Analysis of Gastric Tumors

Check if the same lab product or an alternative is used in the 5 most similar protocols
All data were transferred to GE AW 4.6 workstation (GE Healthcare, Milwaukee, WI, USA), and interpreted by two radiologists with 6 and 10 years of experience in gastrointestinal radiology. Data analysis was carried out independently using GSI Viewer software (GE Healthcare, Milwaukee, WI, USA) with a standard soft-tissue window (WL 40 and WW 400). Regions of interest (ROI) were drawn on the solid part of the tumor (about two-thirds of the area), with the exclusion of peripheral fat, visible vessel, calcification and cystic/necrotic areas. A circular ROI was placed into the aortic arch within the same CT slice, after the exclusion of calcified atherosclerotic plaque. Subsequently, the thickness of tumour was measured and recorded. In order to reduce the individual variation between patients, IC value was normalized by dividing the IC of lesion to that of aorta (nIC=IClesion/ICaorta) [12 (link)]. All IC values were repeatedly measured three times, and the average value was then calculated. Similarly, ROI of the three gastric regions (fundus, body and antrum) was measured for three times, and their average values were calculated.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!