The largest database of trusted experimental protocols

Mdo3102

Manufactured by Tektronix

The MDO3102 is a Mixed Domain Oscilloscope from Tektronix. It combines a 1 GHz oscilloscope, a 3 GHz spectrum analyzer, and a 200 MHz logic analyzer in a single instrument. The device features a 9-inch WVGA color display and a comprehensive set of measurement capabilities.

Automatically generated - may contain errors

2 protocols using mdo3102

1

Monitoring Coal Crack Depth using PZT Sensors

Check if the same lab product or an alternative is used in the 5 most similar protocols
As shown in Fig. 1, the experimental equipment includes: arbitrary function generator (RIGOL DG1062Z), signal amplifier (PINTECH HA-520), oscilloscope (Tektronix MDO3102), PZT patch and the sample of coal with size of 100 mm × 50 mm × 50 mm. As shown in Fig. 2, the width of the crack was about 2 mm in the middle of the sample, and the depth were 0 mm, 5 mm, 10 mm, 20 mm and 40 mm respectively.

Coal crack monitoring system based on PZT sensor.

The coal samples tested.

+ Open protocol
+ Expand
2

Comprehensive Characterization of Optoelectronic Devices

Check if the same lab product or an alternative is used in the 5 most similar protocols
The materials and devices were characterized using an optical microscope (Nikon ECLIPSE LV100ND), aberration-corrected TEM (Thermo ScientificTM, Titan Cube Themis G2), with the operating voltage at 300 kV and Super-X detector system for Energy-Dispersive X-ray spectrometry (EDX) mappings, and an X-ray photoelectron spectroscopy analyser (Thermo VG Scientific ESCALAB250). The electrical and optoelectronic performance was measured using a semiconductor analyser (Agilent B1500A), a probe station (Cascade M150) and a laser diode controller (Thorlabs ITC4001, with laser excitations of 405 and 638 nm) in a dark room at room temperature; 405 nm of light was generated using a Thorlabs ITC4001 unit, and a current amplifier (Model SR570) and an oscilloscope (Tektronix MDO3102) were used to provide a gate voltage to characterize the programming and erasing performance. The noise was measured using a noise-measurement system (Fs Pro, 100 kHz bandwidth).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!